IMI Norgren 11-808-980 G1 Pilot-Operated Pressure Regulator
IMI Norgren 11-808-980 is a G1 relieving pilot-operated air regulator with a 20 bar maximum inlet rating.
Description
The G1 11-808-980 is the larger-port entry in this pair of 11-808 standard models. Its separate pilot connection allows the pressure-setting control to be placed apart from the main air-line installation.
Selection Notes for 11-808-980
Check the pilot port and gauge take-off as well as the G1 line connection. If a gauge is fitted, apply the lower published temperature limit for the gauge-equipped version rather than the bare regulator limit.
11-808-980 Flow and Temperature Data
| Parameter | Verified value |
|---|---|
| Main port / diaphragm | G1 / relieving |
| Typical flow | 180 dm^3/s with feedback pilot at 8 bar inlet and 6.3 bar outlet, minimal drop |
| Maximum inlet | 20 bar |
| Ambient / medium, without gauge | -20 to +80 degrees C |
| Version with gauge | -20 to +65 degrees C |
| Weight | 2.1 kg |
11-808 Pilot, Gauge and Bracket Reference
| Item | Catalogue detail |
|---|---|
| Pilot port | Rc1/4 |
| Gauge port | Rc1/8 or 1/8 NPT plugged, as marked in drawing |
| Wall mounting bracket | 18-001-027; separate accessory |
| Bracket slot spacing | 83 mm in mounting drawing |
Constant-Bleed Pilot-Operated Design
The 11-808 is a constant-bleed type for compressed air. Allow for the pneumatic control circuit and dry the supply sufficiently to avoid icing below +2 degrees C.
Gauge Choice Needs Its Own Range Check
The accessory page offers several gauge scales. Select the scale and connection for the intended outlet setting; a listed gauge is not automatically included with 11-808-980.
Functional Check After Replacement
After fitting the replacement, follow the equipment commissioning procedure before returning the machine to normal operation. Where applicable, test under controlled conditions and observe response, movement, signals, leakage, and connection stability. Check the installation again after its initial run to identify any adjustment that may be needed.
Order Detail Confirmation
To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.
Additional information
| Model | 11-808-980 |
|---|---|
| Function | Pilot-operated pressure regulator |
| Main port | G1 |
| Gauge port | Rc1/8 |