IMI Norgren 11-818-993 G1/4 Precision Regulator with R1/4 Gauge Port
IMI Norgren 11-818-993 combines a 0.07 to 4 bar precision-regulation range with an R1/4 gauge port.
Description
Local pressure indication is the distinguishing catalogue feature of suffix 993. It retains the standard-pressure range while adding the gauge connection identified in the exact model table.
Selection Notes for 11-818-993
Plan the gauge connection and scale before ordering accessories. The carton also says REG MAX SET 70 PSI, while the body and exact manufacturer row give 0.07 to 4 bar; retain both observations and do not advertise the carton wording as a verified operating range.
Verification Notes
- Carton says REG MAX SET 70 PSI; do not replace the body/PDF operating range 0.07-4 bar with that carton marking. Meaning of adjustment-stop wording beyond the printed text is not independently verified.
11-818-993 Gauge-Ready Exact Variant
| Feature | Catalogue value |
|---|---|
| Main port | G1/4 |
| Gauge port | R1/4 |
| Pressure range | 0.07 to 4 bar |
| Typical accuracy | 0.03 bar at the stated 7 bar inlet / 2 dm^3/s test |
| Relieving / weight | Standard / 0.64 kg |
11-818 Gauge Accessory Reference
| Accessory | Published detail |
|---|---|
| 40 mm gauge, 0 to 4 bar | 18-015-990; R1/8 connection |
| Gauge connection adaptation | Catalogue requires an R1/4-to-G1/8 reducing adaptor for the listed gauges |
| Supply boundary | Gauge and adaptor are separate accessory selections |
Use the Gauge-Port Model Callout
The dimension sheet specifically calls out an R1/4 gauge port for 11-818-987, 11-818-993 and 11-818-991. This is a model-specific connection, not a generic claim for every 11-818.
Read the Body Range Alongside the Carton
The exact manufacturer row and the photographed body agree on 0.07 to 4 bar. Keep the separate 70 PSI carton wording in the audit trail rather than advertising it as the verified regulation range.
Functional Check After Replacement
After fitting the replacement, follow the equipment commissioning procedure before returning the machine to normal operation. Where applicable, test under controlled conditions and observe response, movement, signals, leakage, and connection stability. Check the installation again after its initial run to identify any adjustment that may be needed.
Order Detail Confirmation
To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.
Additional information
| Model | 11-818-993 |
|---|---|
| Function | Precision pressure regulator |
| Main port | G1/4 |
| Outlet range | 0.07 to 4 bar |
| Gauge port | R1/4 |