IMI Norgren 0882200 18D G1/4 Hydraulic Pressure Switch, 10 to 160 bar
Norgren 0882200 is a threaded G1/4 hydraulic switch for a 10 to 160 bar setpoint band.
Description
This mid-range DIN version uses a fixed switching difference. Plan for the recovery point before specifying a circuit that cycles near the pressure trip.
0882200 Configuration
| Model | 0882200 |
|---|---|
| Marked model | 0882200 |
| Pressure connection | G1/4 |
| Setpoint range | 10 to 160 bar |
| Differential | Fixed |
| Marked Pmax | 400 bar |
Selection Notes for 0882200
Compare required trip and recovery with the range-end values. They are not a formula for the differential at an intermediate setpoint.
Threaded Model Switching Difference
| Published band | Lower-range difference | Upper-range difference |
|---|---|---|
| 10 to 160 bar | 11 bar | 17 bar |
Threaded Body Fit: Drawing 1
| Selection criterion | Catalogue information |
|---|---|
| Body width | 30 mm |
| Main body length dimension | 72 mm |
| Port-end extension shown | 7.5 mm |
| Port wrench flats | 27 mm |
Setpoint Placement
The applicable table uses atmospheric pressure as reference and recommends a setpoint near the middle of the band where practicable. The 400 bar nameplate maximum does not extend the adjustment span.
Leave Room for the DIN Connector
Compare the threaded body envelope and confirm room for the electrical plug. The drawing also illustrates an M12 option, but the selected G1/4 code is in the DIN table.
Installation Preparation
Prepare the equipment according to the site procedure and the manufacturer's instructions before installing this part. Where relevant, isolate power and pressure sources, then check the mounting direction, connection points, and sealing arrangement. After installation, inspect the completed connections before beginning a controlled functional test.
Order Detail Confirmation
To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.
Additional information
| Model | 0882200 |
|---|---|
| Marked model | 0882200 |
| Pressure connection | G1/4 |
| Setpoint range | 10 to 160 bar |
| Differential | Fixed |
| Marked Pmax | 400 bar |