IMI Norgren 0883100 18D Flange Hydraulic Pressure Switch, 5 to 70 bar

Norgren 0883100 is a 5 to 70 bar 18D hydraulic switch with a flange process interface.

Request a Quote

SKU: 0883100 Category: Tags: , Brand:

Description

Pressure enters through the mating face rather than a threaded end. Use the flange drawing for inlet and seal position when reviewing a manifold replacement.

Request a Quote

0883100 Configuration

Model 0883100
Marked model 0883100
Pressure interface Flange
Setpoint range 5 to 70 bar
Catalogue drawing 2
Electrical interface DIN Form A

Selection Notes for 0883100

Compare the mounting face and allow clearance for the Form A plug. A threaded switch with the same band is not a mechanical match.

5 to 70 bar Flange Drawing

Drawing 2 feature Dimension
Body width 30 mm
Body length dimension shown 72 mm
Mounting centers shown 20 mm
Face inlet recess 8 mm diameter
O-ring designation 5 x 1.5 mm

DIN Form A Switching Function for Manifold Controls

Selection criterion Catalogue information
Microswitch function SPDT
Closes on rising pressure Terminals 1 to 3
Opens on rising pressure Terminals 1 to 2
Persistent DC current at the listed voltage 0.1 A at 30 V DC

Read the Flange Row

Model 0883100 is assigned to drawing 2. The 10.5 and 15 bar figures are switching differences at the range ends, not available setpoints.

Match the Contact to the Manifold Circuit

Select the opening or closing contact for the intended pressure signal. The M12 diagram uses different terminal numbering and is not the wiring reference for the selected DIN version.

Functional Check After Replacement

After fitting the replacement, follow the equipment commissioning procedure before returning the machine to normal operation. Where applicable, test under controlled conditions and observe response, movement, signals, leakage, and connection stability. Check the installation again after its initial run to identify any adjustment that may be needed.

Product Inquiry Support

We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.

Additional information

Model

0883100

Marked model

0883100

Pressure interface

Flange

Setpoint range

5 to 70 bar

Catalogue drawing

2

Electrical interface

DIN Form A