IMI Norgren 102GA2828 G1/4 Pilot-Operated Check Valve
The IMI Norgren 102GA2828 is a G1/4 pilot-operated check valve with a G1/8 pilot port. Confirm pilot pressure and one-way blocking behavior in the circuit.
Description
Model 102GA2828 is the G1/4 main-port entry in the 102GA pilot-operated check-valve table, with a G1/8 pilot port. With pilot pressure applied at port 12, the valve permits flow in both directions; without pilot pressure, the internal non-return function permits one-way flow.
102GA2828 Configuration
| Manufacturer | IMI Norgren |
|---|---|
| Part code | 102GA2828 |
| Function | Pilot-operated check valve |
| Main port 1 | G1/4 |
| Main port 2 | G1/4 |
| Pilot port | G1/8 |
| Minimum pilot pressure | 1 bar |
| Catalogue weight | 77 g |
Selection Notes
Confirm both G1/4 main connections, the G1/8 pilot line and the operating-pressure ratio. The catalogue requires pilot pressure of at least 50% of operating pressure and lists 1 bar as the minimum for this exact row. Review the response to loss of pilot pressure in the complete machine safety design.
Exact 102GA2828 Ports and Pilot Requirement
| Parameter | Catalogue value |
|---|---|
| Main port 1 | G1/4 |
| Main port 2 | G1/4 |
| Pilot port | G1/8 |
| Minimum pilot pressure | 1 bar; pilot pressure must also be at least 50% of operating pressure |
Applicable 102GA Service and Materials
| Parameter | Catalogue specification |
|---|---|
| Medium | Compressed air |
| Operating pressure | 1 to 10 bar |
| Ambient/media temperature | 0 to +80 degrees C |
| Main body and pilot cover | Brass |
| Female-thread housing | Zinc die-casting |
| Valve and springs | Stainless steel; valve includes NBR |
| Sealing | NBR |
| Dry-air condition | Air must be sufficiently dry to prevent ice below +2 degrees C |
Exact 102GA2828 ISO G Dimensions
| Drawing parameter | Metric value |
|---|---|
| C(mm) | 26.0 |
| C1(mm) | 9.5 |
| E(mm) | 48.9 |
| E1(mm) | 21.3 |
| G(mm) | 6.6 |
| K diameter(mm) | 18.0 |
| AF(mm) | 17 |
| AF1(mm) | 19 |
| AF2(mm) | 12 |
| Weight(g) | 77 |
Pilot Operation and Safe-System Note
This is an essentially pilot-operated check valve. With pilot pressure applied at port 12 it allows flow in both directions; after pilot pressure is removed, flow proceeds in one direction only. When used in pairs, blocking fittings can control an actuator after electrical failure, air failure or tube breakage, but designers must consider all conditions and safeguards.
Pilot Pressure Requirement
The brochure states that pilot pressure must be at least 50% of operating pressure and provides a minimum pilot pressure value in the exact model row. Confirm the application's operating pressure and ensure the pilot circuit meets both requirements.
Industrial Service and Failure Modes
The manufacturer limits these products to industrial compressed-air systems within the published pressure and temperature conditions. Consider component failure modes and provide appropriate safeguards in the complete system.
Spare Parts Records
Keeping a clear record of installed components can make future maintenance and purchasing more efficient. For this product, record the brand, full model code, important specifications, and equipment location. Update the record whenever a component or machine configuration changes, so the next replacement decision is based on current information.
Order Detail Confirmation
To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.
Additional information
| Model | 102GA2828 |
|---|---|
| Brand | Norgren |
| Function | Pilot-operated check valve |
| Main ports | G1/4 / G1/4 |
| Pilot port | G1/8 |
| Minimum pilot pressure | 1 bar |
| Catalogue weight | 77 g |