IMI Norgren 102GA3838 G3/8 Pilot-Operated Check Valve
The IMI Norgren 102GA3838 is a G3/8 pilot-operated check valve with a G1/8 pilot port. Confirm pilot pressure and one-way blocking behavior in the circuit.
Description
Model 102GA3838 is the G3/8 main-port entry in the 102GA pilot-operated check-valve table, with a G1/8 pilot port. With pilot pressure applied at port 12, the valve permits flow in both directions; without pilot pressure, the internal non-return function permits one-way flow.
102GA3838 Configuration
| Manufacturer | IMI Norgren |
|---|---|
| Part code | 102GA3838 |
| Function | Pilot-operated check valve |
| Main port 1 | G3/8 |
| Main port 2 | G3/8 |
| Pilot port | G1/8 |
| Minimum pilot pressure | 1 bar |
| Catalogue weight | 128 g |
Selection Notes
Confirm both G3/8 main connections, the G1/8 pilot line and the operating-pressure ratio. The catalogue requires pilot pressure of at least 50% of operating pressure and lists 1 bar as the minimum for this exact row. Review the response to loss of pilot pressure in the complete machine safety design.
Exact 102GA3838 Ports and Pilot Requirement
| Parameter | Catalogue value |
|---|---|
| Main port 1 | G3/8 |
| Main port 2 | G3/8 |
| Pilot port | G1/8 |
| Minimum pilot pressure | 1 bar; pilot pressure must also be at least 50% of operating pressure |
Applicable 102GA Service and Materials
| Parameter | Catalogue specification |
|---|---|
| Medium | Compressed air |
| Operating pressure | 1 to 10 bar |
| Ambient/media temperature | 0 to +80 degrees C |
| Main body and pilot cover | Brass |
| Female-thread housing | Zinc die-casting |
| Valve and springs | Stainless steel; valve includes NBR |
| Sealing | NBR |
| Dry-air condition | Air must be sufficiently dry to prevent ice below +2 degrees C |
Exact 102GA3838 ISO G Dimensions
| Drawing parameter | Metric value |
|---|---|
| C(mm) | 30.3 |
| C1(mm) | 11.6 |
| E(mm) | 56.7 |
| E1(mm) | 24.8 |
| G(mm) | 7.2 |
| K diameter(mm) | 23.0 |
| AF(mm) | 20 |
| AF1(mm) | 24 |
| AF2(mm) | 12 |
| Weight(g) | 128 |
Pilot Check Function
At port 12 pilot pressure, the blocking valve allows flow in both directions; when pilot pressure is removed, an internal non-return valve permits flow in one direction only. Apply this behaviour to the machine design only after confirming the actual circuit and safety requirements.
System Safety Context
The brochure notes that paired blocking fittings may help control an actuator during electrical failure, air failure or tube breakage. This is not a guarantee of safe isolation; the designer must assess all failure modes and provide safeguards for the complete pneumatic system.
Industrial Service and Failure Modes
The manufacturer limits these products to industrial compressed-air systems within the published pressure and temperature conditions. Consider component failure modes and provide appropriate safeguards in the complete system.
Documentation Before Ordering
If the original part has an unclear suffix or incomplete marking, gather the available information before placing an order. Photos of the nameplate, the equipment manual, previous purchase records, and connection details can help narrow down the correct version. Keep any specification that remains uncertain open for confirmation instead of assuming a match.
Payment Arrangements
The payment method is confirmed as part of the order arrangement. International orders may be settled in USD by T/T, PayPal, or another mutually agreed method. For payments in RMB within mainland China, Alipay QR code and WeChat Pay QR code arrangements are also available. The applicable option is agreed before order processing.
Additional information
| Model | 102GA3838 |
|---|---|
| Brand | Norgren |
| Function | Pilot-operated check valve |
| Main ports | G3/8 / G3/8 |
| Pilot port | G1/8 |
| Minimum pilot pressure | 1 bar |
| Catalogue weight | 123 g |