IMI Norgren T60C4890 G1/2 Excess-Flow Air Fuse
T60C4890: G1/2 excess-flow shut-off valve with 68.2 SCFM shut-off flow at 100 psi, automatic reset and an aluminum body.
Description
The T60C4890 is an in-line air fuse for a flexible pneumatic hose. It is selected by shut-off performance as well as connection size.
Selection Notes for T60C4890
Confirm hose length, bore, available supply pressure and required trip behavior together; port size alone does not establish suitability.
Flow and Trip Characteristics
| Parameter | Value |
|---|---|
| Connection | G1/2, ISO G |
| Shut-off flow rate | 68.2 SCFM at 100 psi supply |
| Pressure drop at shut-off flow | 2.0 psi |
| Flow at 100 psi supply and 1 psi differential | 49.2 SCFM |
| Weight | 5.3 oz |
Service Conditions
| Parameter | Value |
|---|---|
| Medium | Filtered compressed air or inert gases; lubricated or non-lubricated |
| Maximum pressure | 16 bar (232 psi) |
| Minimum pressure | Depends on hose length and internal diameter |
| Operating temperature | -20 to 80 degrees C |
| Cold operation | Avoid freezing conditions; confirm use below 2 degrees C |
Materials
| Parameter | Value |
|---|---|
| Body | Aluminum |
| Internal parts | Brass |
| Spring | Stainless steel |
Installation and Reset
| Parameter | Value |
|---|---|
| Position in circuit | Between fixed supply pipework and the flexible hose |
| Protected section | Hose downstream of the air fuse |
| Orientation | Install in the correct flow direction |
| Reset behavior | Automatic after the failure is corrected |
Excess-Flow Operation
The T60C4890 closes when the flow reaches its shut-off condition, helping limit air loss from a failed downstream hose. At 100 psi supply its shut-off flow is 68.2 SCFM with a 2.0 psi differential. The normal-flow value of 49.2 SCFM is specified at a different, 1 psi differential and is not the trip setting.
Positioning in the Air Line
Install the valve directly between fixed supply pipework and the flexible hose, with the marked flow direction observed. Only the hose downstream of the valve is protected. If an upstream shut-off valve is fitted, open it slowly to control the initial surge and avoid an unintended trip.
Hose and Supply Selection
Match the nominal valve size to the hose and evaluate hose length, internal diameter and available supply pressure together. The supply must deliver enough flow to activate the air fuse under a hose-failure condition. A long or restrictive hose can change the pressure required for reliable operation.
Automatic Reset and Commissioning
A small residual flow allows the valve to reset automatically after the fault is corrected. Confirm normal equipment operation and the shut-off response during controlled commissioning. The aluminum body, brass internals and stainless steel spring are intended for filtered pneumatic service.
Product Inquiry Support
We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.
Additional information
| Model | T60C4890 |
|---|---|
| Connection | G1/2 |
| Maximum pressure | 16 bar |
| Shut-off flow | 68.2 SCFM at 100 psi |
| Shut-off differential | 2.0 psi |