IMI Norgren B72G-3AK-QT3-RMN 3/8 PTF Excelon Filter Regulator

B72G-3AK-QT3-RMN: 3/8 PTF modular filter regulator with 40 micron filtration, a quarter-turn manual drain and a 0.3 to 10 bar (5 to 150 psig) outlet range.

Request a Quote

SKU: B72G-3AK-QT3-RMN Category: Tags: , Brand:

Description

The B72G-3AK-QT3-RMN. The Excelon B72G combines a relieving regulator with a 40 micron filter element. This configuration has a transparent polycarbonate bowl, a push-to-lock pressure knob and no supplied gauge.

Request a Quote

Selection Notes for B72G-3AK-QT3-RMN

Match the 3/8 PTF line connection and keep inlet pressure at or below 10 bar (150 psig). If panel mounting, allow a 1.57 in opening and 7.83 in below the port centerline to remove the bowl.

Port, filtration and pressure setting

Specification Value
Inlet and outlet 3/8 PTF
Adjustment Push-to-lock knob
Diaphragm Relieving
Outlet adjustment 0.3 to 10 bar (5 to 150 psig)
Element 40 micron
Bowl Transparent polycarbonate bowl
Drain Quarter-turn manual
Gauge No gauge supplied

Operating limits and materials

Specification Value
Medium Compressed air and neutral gases
Maximum inlet pressure 10 bar (150 psig)
Operating temperature -34 to 50 deg C
Body Zinc
Bonnet Acetal
Filter element Sintered polypropylene
Valve Polypropylene and TPV
Elastomers Chloroprene and nitrile

Mounting envelope and bowl access

Dimension Inches
Port centerline to bottom of drain 5.83
Minimum bowl removal clearance below port centerline 7.83
Port centerline to top of adjuster 2.87
Width across line ports 1.97
Body depth without gauge 1.89
Panel opening diameter 1.57
Panel thickness 0 to 0.16

Compatible service and mounting parts

Specification Value
Replacement element 5925-02 (40 micron)
Relieving regulator service kit 4383-500
Wall mounting bracket 4224-50
Neck mounting bracket 74316-50
Panel nut 4248-89
Quickclamp connector 4214-51
0 to 160 psig gauge 18-015-212 (optional)

Bowl and drainage

The transparent polycarbonate bowl lets you see condensate without a separate level indicator. The quarter-turn drain provides manual control of condensate discharge. Keep the drain accessible after installation.

Installation and servicing

Install in-line or connect to compatible Excelon components with Quickclamp 4214-51. The bayonet bowl needs 7.83 in of clearance below the port centerline for removal. Use element 5925-02 to retain the original 40 micron rating and service kit 4383-500 for the relieving regulator.

Product Inquiry Support

We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.

Additional information

Model

B72G-3AK-QT3-RMN

Series

Excelon

Port

3/8 PTF

Filtration

40 micron

Drain

Quarter-turn manual

Bowl

Transparent polycarbonate bowl

Outlet adjustment

0.3 to 10 bar (5 to 150 psig)

Maximum inlet pressure

10 bar (150 psig)

Gauge

No gauge supplied