FESTO CMMP-AS-C10-11A-P3 551024 Motor Controller

The Festo CMMP-AS-C10-11A-P3 is a motor controller for servo motors. The datasheet identifies a three-phase 400 V AC nominal operating supply, 10 A nominal output current, and a 6,000 VA nominal controller power.

SKU: 551024 Category: Tags: , , Brand:

Description

FESTO CMMP-AS-C10-11A-P3 551024 Motor Controller

The Festo CMMP-AS-C10-11A-P3 is a motor controller for servo motors. The datasheet identifies a three-phase 400 V AC nominal operating supply, 10 A nominal output current, and a 6,000 VA nominal controller power.

Key Features

  • Three-phase 400 V AC nominal operating voltage
  • 10 A nominal output current
  • 6,000 VA nominal controller power
  • 24 V DC nominal logic power supply

Technical Data

Brand FESTO
Model CMMP-AS-C10-11A-P3
Part number 551024
Mains filter Integrated
Safety function Safe Torque off (STO)
Safety Integrity Level (SIL) Safe torque off (STO)/SIL 2
Performance level (PL) Safe torque off (STO)/category 3, performance level d
Display Seven-segment display
Output frequency 0 … 1,000 Hz
Output voltage range AC 0 – 360 V
Braking resistance 68 Ohm
Braking resistance pulse power 8.5 kVA
Max. current, digital logic outputs 100 mA
Max. peak current duration 3 s
Max. intermediate circuit voltage, DC 560 V
Nominal output current 10 A
Nominal operating voltage, AC 400 V
Nominal controller power 6,000 VA
Nominal DC voltage, logic power supply 24 V
Nominal current 11 A
Line frequency 50 … 60 Hz
Parameters configuring interface Parameters configuration and commissioning
Control interface (PtP)
RS232 (9600…115000 Bits/s)
Nominal operating voltage, phases Three-phase
Peak power 12,000 VA
Effective peak current per phase 20 A
Current consumption, logic power supply without clamping brake 1 A
Max. current consumption for logic supply, holding brake and I/O 3.5 A
Storage temperature -25 … 70 °C
Relative air humidity 0 – 90 %
Protection class IP20
Ambient temperature 0 … 50 °C
Product weight 3,700 g
Number of analogue monitor outputs 2
Number of analogue setpoint inputs 3
Number of 24 V DC digital logic outputs 5
Number of digital logic inputs 10
Communications profile DS301/DSP402
FHPP
Process interface I/O coupling
For 255 positioning records
Encoder interface output, characteristics Resolution 16384 ppr
Encoder interface input, characteristics RS422
EnDat 2.2
Encoder interface output, function Actual value feedback via encoder signals in speed control mode
Setpoint specification for downstream slave drive unit
Encoder interface input, function Encoder signal, speed setpoint in RPM
In synchronous operation as specified speed in RPM for the slave drive unit
Setpoint position value as encoder signal
Fieldbus coupling CANopen
DeviceNet
Ethernet
Profibus DP
Sercos
Max. fieldbus transmission speed 1 Mbit/s
Mounting type on mounting plate
Tightened

Application Notes

Use this exact model only after confirming the complete part number, electrical supply, installed interfaces and environmental limits against the equipment documentation. Similar series members may have different ratings or communication options.

Selection and Installation

Compare the original nameplate and connection layout with the datasheet for this part number. Follow Festo and machine manufacturer instructions for wiring, mounting and commissioning. Confirm any uncertain option or suffix before energising the equipment.

Inquiry

For a quotation or replacement enquiry, provide model CMMP-AS-C10-11A-P3, part number 551024, quantity, destination and clear photos of the installed unit where available.

Electrical Supply Matching

The datasheet specifies a three-phase 400 V AC nominal operating voltage and a separate 24 V DC nominal logic supply. Confirm both supplies and the motor connection when assessing this controller for replacement.

Maintenance Inspection

Before replacing CMMP-AS-C10-11A-P3, examine the existing installation for issues that may affect the new part. Check the original label, ports, seals, fittings, cables, and mounting points as applicable. Finding a leak, worn connection, or loose contact before installation can help avoid repeating the same problem after replacement.

Product Inquiry Support

We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.

Additional information

Brand

FESTO

Model

CMMP-AS-C10-11A-P3

Part Number

551024

Mains filter

Integrated

Safety function

Safe Torque off (STO)

Safety Integrity Level (SIL)

Safe torque off (STO)/SIL 2

Performance level (PL)

Safe torque off (STO)/category 3, performance level d

Display

Seven-segment display

Output frequency

0 … 1,000 Hz

Output voltage range AC

0 – 360 V

Braking resistance

68 Ohm