FESTO CMMS-AS-C4-3A 552741 Motor Controller
The Festo CMMS-AS-C4-3A is a motor controller for servo motors. The datasheet lists a single-phase 230 V AC nominal operating voltage, 4 A nominal output current, and 600 VA nominal controller power.
Description
FESTO CMMS-AS-C4-3A 552741 Motor Controller
The Festo CMMS-AS-C4-3A is a motor controller for servo motors. The datasheet lists a single-phase 230 V AC nominal operating voltage, 4 A nominal output current, and 600 VA nominal controller power.
Key Features
- Single-phase 230 V AC nominal operating voltage
- 4 A nominal output current
- 600 VA nominal controller power
- 24 V DC nominal logic power supply
Technical Data
| Brand | FESTO |
|---|---|
| Model | CMMS-AS-C4-3A |
| Part number | 552741 |
| Active PFC | No |
| Mains filter | Integrated |
| Safety function | EN 954-1 Cat 3, Safety Stop |
| Display | Seven-segment display |
| Output frequency | 0 … 1,000 Hz |
| Output voltage range AC | 0 – 210 V |
| Braking resistor, external | 100 Ohm |
| Braking resistor, integrated | 230 Ohm |
| Braking resistance pulse power | 0.7 kVA |
| Max. current, digital logic outputs | 100 mA |
| Max. nominal input current | 5 A |
| Max. length of motor cable without external mains filter | 15 m |
| Max. peak current duration | 2 s |
| Max. intermediate circuit voltage, DC | 380 V |
| Nominal output current | 4 A |
| Nominal operating voltage, AC | 230 V |
| Input voltage range AC | 95 … 255 V |
| Nominal controller power | 600 VA |
| Nominal DC voltage, logic power supply | 24 V |
| Nominal current | 4 A |
| Line frequency | 50 … 60 Hz |
| Parameters configuring interface | Parameters configuration and commissioning Control interface (PtP) RS232 (9600…115000 Bits/s) |
| Nominal operating voltage, phases | Single-phase |
| Peak current | 10 A |
| Current consumption, logic power supply without clamping brake | 0.35 A |
| Storage temperature | -25 … 70 °C |
| Protection class | IP20 |
| Ambient temperature | 0 … 50 °C |
| Product weight | 2,500 g |
| Number of analogue outputs | 1 |
| Number of analogue inputs | 1 |
| Number of 24 V DC digital logic outputs | 5 |
| Number of digital logic inputs | 14 |
| Communications profile | DS301/DSP402 FHPP |
| Process interface | I/O coupling for 64 position sets |
| Encoder interface output, characteristics | Resolution 4096 ppr |
| Encoder interface input, characteristics | EnDat 2.2 |
| Encoder interface output, function | Actual value feedback via encoder signals in speed control mode Setpoint specification for downstream slave drive unit |
| Encoder interface input, function | Setpoint position value as encoder signal |
| Fieldbus coupling | CANopen DeviceNet Profibus DP |
| Max. fieldbus transmission speed | 1 Mbit/s |
| Mounting type | Mounting plate, bolted |
Application Notes
Use this exact model only after confirming the complete part number, electrical supply, installed interfaces and environmental limits against the equipment documentation. Similar series members may have different ratings or communication options.
Selection and Installation
Compare the original nameplate and connection layout with the datasheet for this part number. Follow Festo and machine manufacturer instructions for wiring, mounting and commissioning. Confirm any uncertain option or suffix before energising the equipment.
Inquiry
For a quotation or replacement enquiry, provide model CMMS-AS-C4-3A, part number 552741, quantity, destination and clear photos of the installed unit where available.
Supply and Output Rating
The CMMS-AS-C4-3A datasheet lists a single-phase 230 V AC nominal operating voltage, 4 A nominal output current and a separate 24 V DC nominal logic supply. Match these values to the installed motor and power wiring.
Installation Preparation
Prepare the equipment according to the site procedure and the manufacturer's instructions before installing this part. Where relevant, isolate power and pressure sources, then check the mounting direction, connection points, and sealing arrangement. After installation, inspect the completed connections before beginning a controlled functional test.
Payment Arrangements
The payment method is confirmed as part of the order arrangement. International orders may be settled in USD by T/T, PayPal, or another mutually agreed method. For payments in RMB within mainland China, Alipay QR code and WeChat Pay QR code arrangements are also available. The applicable option is agreed before order processing.
Additional information
| Brand | FESTO |
|---|---|
| Model | CMMS-AS-C4-3A |
| Part Number | 552741 |
| Active PFC | No |
| Mains filter | Integrated |
| Safety function | EN 954-1 Cat 3, Safety Stop |
| Display | Seven-segment display |
| Output frequency | 0 … 1,000 Hz |
| Output voltage range AC | 0 – 210 V |
| Braking resistor, external | 100 Ohm |
| Braking resistor, integrated | 230 Ohm |