FESTO CMMS-AS-C4-3A-G2 572986 Motor Controller
The Festo CMMS-AS-C4-3A-G2 is a motor controller for servo motors. Its datasheet specifies a single-phase 230 V AC nominal supply, 4 A nominal output current, 600 VA nominal controller power and safe torque off (STO).
Description
FESTO CMMS-AS-C4-3A-G2 572986 Motor Controller
The Festo CMMS-AS-C4-3A-G2 is a motor controller for servo motors. Its datasheet specifies a single-phase 230 V AC nominal supply, 4 A nominal output current, 600 VA nominal controller power and safe torque off (STO).
Key Features
- Single-phase 230 V AC nominal operating voltage
- 4 A nominal output current
- 600 VA nominal controller power
- Safe torque off (STO) listed for this model
Technical Data
| Brand | FESTO |
|---|---|
| Model | CMMS-AS-C4-3A-G2 |
| Part number | 572986 |
| Active PFC | No |
| Mains filter | Integrated |
| Safety function | Safe torque off (STO) |
| Performance level (PL) | Safe torque off (STO)/category 3, performance level d |
| Display | Seven-segment display |
| Output frequency | 0 … 1,000 Hz |
| Output voltage range AC | 0 V up to input voltage |
| Braking resistor, external | 100 Ohm |
| Braking resistor, integrated | 230 Ohm |
| Setpoint input impedance | 20 kOhm |
| Braking resistance pulse power | 0.7 kVA |
| Max. current, digital logic outputs | 100 mA |
| Max. nominal input current | 5 A |
| Max. length of motor cable without external mains filter | 15 m |
| Max. peak current duration | 2 s |
| Max. intermediate circuit voltage, DC | 320 V |
| Nominal output current | 4 A |
| Nominal operating voltage, AC | 230 V |
| Input voltage range AC | 95 … 250 V |
| Nominal controller power | 600 VA |
| Nominal DC voltage, logic power supply | 24 V |
| Parameters configuring interface | Parameters configuration and commissioning Control interface (PtP) RS232 (9600…115000 Bits/s) |
| Nominal operating voltage, phases | Single-phase |
| Peak current | 10 A |
| Current consumption, logic power supply without clamping brake | 0.35 A |
| Storage temperature | -25 … 70 °C |
| Protection class | IP10 IP20 |
| Ambient temperature | 0 … 50 °C |
| Note on ambient temperature | Power must be reduced by 4% per °C at ambient temperatures above 40° C. |
| Product weight | 1,500 g |
| Number of analogue outputs | 1 |
| Number of analogue inputs | 1 |
| Number of 24 V DC digital logic outputs | 5 |
| Number of digital logic inputs | 14 |
| Communications profile | DS301/DSP402 FHPP |
| Process interface | I/O coupling for 64 position sets |
| Encoder interface output, characteristics | Resolution 4096 ppr |
| Encoder interface input, characteristics | EnDat 2.2 |
| Encoder interface output, function | Actual value feedback via encoder signals in speed control mode Setpoint specification for downstream slave drive unit |
| Encoder interface input, function | Setpoint position value as encoder signal |
| Fieldbus coupling | CANopen DeviceNet Profibus DP |
| Max. fieldbus transmission speed | 1 Mbit/s |
| Mounting type | Mounting plate, bolted |
Application Notes
Confirm the complete model code, the installed mechanical or electrical interface and the operating limits against the original equipment. Similar products within a series can differ in pressure, supply, output, mounting or communication.
Selection and Installation
Compare the original nameplate, the part number and the product-specific datasheet. Follow Festo and machine manufacturer instructions for mounting, connections and controlled commissioning. Clarify any uncertain option or suffix before ordering.
Inquiry
For a quotation or replacement enquiry, provide model CMMS-AS-C4-3A-G2, part number 572986, quantity, destination and clear photos of the original unit when available.
Ambient Temperature Derating
Festo states that power must be reduced by 4% per °C when the ambient temperature exceeds 40 °C. Review the installation temperature and load before replacing or commissioning this controller.
Operating Conditions Check
Before selecting CMMS-AS-C4-3A-G2, confirm that the actual operating conditions fall within the specifications for the exact version being ordered. Relevant factors may include supply voltage, pressure, temperature, medium, and operating frequency, depending on the product type. Do not apply a series-wide maximum rating to an individual variant without checking its documentation.
Product Inquiry Support
We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.
Additional information
| Brand | FESTO |
|---|---|
| Model | CMMS-AS-C4-3A-G2 |
| Part Number | 572986 |
| Active PFC | No |
| Mains filter | Integrated |
| Safety function | Safe torque off (STO) |
| Performance level (PL) | Safe torque off (STO)/category 3, performance level d |
| Display | Seven-segment display |
| Output frequency | 0 … 1,000 Hz |
| Output voltage range AC | 0 V up to input voltage |
| Braking resistor, external | 100 Ohm |