FESTO CMMT-AS-C2-3A-EC-S1 5340819 Servo Drive
The Festo CMMT-AS-C2-3A-EC-S1 is a servo drive with a single-phase 230 V AC nominal operating supply. The datasheet lists 2 A effective nominal current per phase and an EtherCAT fieldbus interface.
Description
FESTO CMMT-AS-C2-3A-EC-S1 5340819 Servo Drive
The Festo CMMT-AS-C2-3A-EC-S1 is a servo drive with a single-phase 230 V AC nominal operating supply. The datasheet lists 2 A effective nominal current per phase and an EtherCAT fieldbus interface.
Key Features
- Single-phase 230 V AC nominal supply
- 2 A effective nominal current per phase
- EtherCAT fieldbus interface
- 24 V DC nominal logic supply
Technical Data
| Brand | FESTO |
|---|---|
| Model | CMMT-AS-C2-3A-EC-S1 |
| Part number | 5340819 |
| Mounting type | Mounting plate, bolted |
| Product weight | 1,300 g |
| Display | LED green/yellow/red |
| Storage temperature | -25 … 55 °C |
| Ambient temperature | 0 … 50 °C |
| Note on ambient temperature | Power must be reduced by 3%/°C at ambient temperatures above 40°C. |
| UL ambient temperature | 0 … 40 °C |
| Relative air humidity | 5 – 90 % non-condensing |
| Protection class | IP20 |
| Overvoltage category | III |
| Nominal operating voltage, phases | Single-phase |
| Nominal operating voltage, AC | 230 V |
| Permissible voltage fluctuation | -20 % / +15 % |
| Input voltage range AC | 100 … 230 V |
| Line frequency | 48 … 62 Hz |
| Nominal current, load supply | 2.8 A |
| Peak current, load supply | 8.4 A |
| Nominal voltage, load supply DC | 320 V |
| Permissible range, load supply | -20 %/+15 % |
| Nominal DC voltage, logic power supply | 24 V |
| Current consumption, logic power supply without clamping brake | 0.5 A |
| Output voltage range AC | 3x (0 – Input) V |
| Effective nominal current per phase | 2 A |
| Effective peak current per phase | 6 A |
| Max. peak current duration | 2 s |
| Nominal controller power | 350 W |
| Number of inputs for motor temperature sensor | 1 |
| Ethernet interface, function | Parameterisation and commissioning |
| Ethernet interface, protocol | TCP/IP |
| Fieldbus interface, protocol | EtherCAT |
| Fieldbus coupling | EtherCAT |
| Communications profile | CiA402 CoE (CANopen over EtherCAT) EoE (Ethernet over EtherCAT) FoE (File over EtherCAT) |
| Process interface | I/O mode for 256 position sets Interpolated Mode CSP Interpolated Mode CST Interpolated Mode CSV |
| Fieldbus interface, transmission rate | 100 Mbit/s |
| Fieldbus interface, type of connection | 2x socket |
| Fieldbus interface, connection technology | RJ45 |
| Encoder interface, function | ENDAT 2.1 encoder ENDAT 2.2 encoder Hiperface encoder Incremental encoder Nikon SIN/COS encoder |
| Encoder interface 2, function | Incremental encoder SIN/COS encoder |
| Encoder interface output, characteristics | 1 MHz maximum output frequency max. 16384 ppr |
| Encoder interface input, characteristics | 1 MHz maximum output frequency max. 16384 ppr |
| Number of digital logic inputs | 12 |
| Number of high-speed logic inputs | 2 |
| Number of 24 V DC digital logic outputs | 6 |
| Number of high-speed switching outputs | 2 |
| Number of floating switching outputs | 1 |
| Number of analogue setpoint inputs | 1 |
| Safety function | Safe brake control (SBC) Safe torque off (STO) Safe stop 1 (SS1) |
| Performance level (PL) | Safe brake control (SBC) / category 3, Performance Level e Safe Torque off (STO)/Category 4, Performance Level e |
| Number of safe 2-pin inputs | 2 |
| Number of diagnostic outputs | 2 |
Application Notes
Confirm the complete model code, the installed mechanical or electrical interface and the operating limits against the original equipment. Similar products within a series can differ in pressure, supply, output, mounting or communication.
Selection and Installation
Compare the original nameplate, the part number and the product-specific datasheet. Follow Festo and machine manufacturer instructions for mounting, connections and controlled commissioning. Clarify any uncertain option or suffix before ordering.
Inquiry
For a quotation or replacement enquiry, provide model CMMT-AS-C2-3A-EC-S1, part number 5340819, quantity, destination and clear photos of the original unit when available.
EtherCAT Interface
The EC-S1 datasheet lists EtherCAT as the fieldbus protocol, with two RJ45 sockets and a 100 Mbit/s transmission rate. Confirm the installed bus type and connector layout before replacement.
Spare Parts Records
Keeping a clear record of installed components can make future maintenance and purchasing more efficient. For this product, record the brand, full model code, important specifications, and equipment location. Update the record whenever a component or machine configuration changes, so the next replacement decision is based on current information.
Order Detail Confirmation
To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.
Additional information
| Brand | FESTO |
|---|---|
| Model | CMMT-AS-C2-3A-EC-S1 |
| Part Number | 5340819 |
| Mounting type | Mounting plate, bolted |
| Product weight | 1,300 g |
| Display | LED green/yellow/red |
| Storage temperature | -25 … 55 °C |
| Ambient temperature | 0 … 50 °C |
| Note on ambient temperature | Power must be reduced by 3%/°C at ambient temperatures above 40°C. |
| UL ambient temperature | 0 … 40 °C |
| Relative air humidity | 5 – 90 % non-condensing |