FESTO VSVA-B-T32C-AZH-A2-1R2L 534781 Solenoid Valve
The Festo VSVA-B-T32C-AZH-A2-1R2L (part number 534781) is a solenoid valve. Its product datasheet lists valve function as 2×3/2 closed monostable and standard nominal flow rate (standardised to din 1343) as 400 l/min.
Description
FESTO VSVA-B-T32C-AZH-A2-1R2L 534781 Solenoid Valve
The Festo VSVA-B-T32C-AZH-A2-1R2L (part number 534781) is a solenoid valve. Its product datasheet lists valve function as 2×3/2 closed monostable and standard nominal flow rate (standardised to din 1343) as 400 l/min.
Key Features
- Valve function: 2×3/2 closed monostable
- Standard nominal flow rate (standardised to DIN 1343): 400 l/min
- pneumatic working port: Sub-base size 18 mm to ISO 15407-1 Sub-base size 02 to VDMA 24563
- Operating voltage: 24 V DC
Technical Data
| Brand | FESTO |
|---|---|
| Model | VSVA-B-T32C-AZH-A2-1R2L |
| Part number | 534781 |
| Valve function | 2×3/2 closed monostable |
| Type of actuation | Electrical |
| Construction width | 18 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 400 l/min |
| pneumatic working port | Sub-base size 18 mm to ISO 15407-1 Sub-base size 02 to VDMA 24563 |
| Operating voltage | 24 V DC |
| Operating pressure | 0.3 MPa … 1 MPa |
| Operating pressure | 3 bar … 10 bar |
| Design | Piston gate valve |
| Type of reset | Pneumatic spring |
| Degree of protection | IP65 |
| Nominal size | 5 mm |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Conforms to standard | ISO 15407-1 VDMA 24563 |
| Manual override | Non-detenting |
| Type of piloting | Piloted |
| Pilot air supply | External |
| Flow direction | Non-reversible |
| lap | Overlap |
| Reverse polarity protection | For all electrical connections |
| Additional functions | Holding current reduction Safety shut-off |
| Signal status display | LED |
| Pilot pressure | 0.3 MPa … 0.8 MPa |
| Pilot pressure | 3 bar … 8 bar |
| Flow rate of valve | 600 l/min |
| Flow rate of valve on individual sub-base | 450 l/min |
| Flow rate of pneumatically interlinked valve | 400 l/min |
| Switching time off | 22 ms |
| Switching time on | 10 ms |
| Operational voltage range DC | 21.6 V … 26.4 V |
| Duty cycle | 100% |
| Max. positive test pulse with 0 signal | 500 µs |
| Max. negative test pulse with 1 signal | 500 µs |
| Characteristic coil data | 24 V DC: low-current phase 1.0 W, high-current phase 2.4 W |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Media temperature | -5 °C … 50 °C |
| Protection against direct and indirect contact | PELV |
| Ambient temperature | -5 °C … 50 °C |
| Max. tightening torque for valve mounting | 0.9 Nm … 1.1 Nm |
| Product weight | 140 g |
| Electrical connection | 4-pin M8x1 Central plug Round design |
| Type of mounting | On sub-base |
| Note on materials | RoHS compliant |
Application Notes
Check the complete model code, installed connections and operating limits against the original equipment. Products in the same series may differ in size, stroke, actuation, pressure range or mounting details.
Selection and Installation
Compare the original nameplate and part number with the product-specific datasheet. Follow the equipment manufacturer instructions for installation and commissioning, and clarify uncertain options before ordering.
Inquiry
For a quotation or replacement enquiry, provide model VSVA-B-T32C-AZH-A2-1R2L, part number 534781, quantity, destination and clear photos of the original unit when available.
Datasheet Selection Note
Festo lists pneumatic working port as Sub-base size 18 mm to ISO 15407-1 Sub-base size 02 to VDMA 24563 for part number 534781. Confirm the full model code and the matching connection, operating range and mounting arrangement against the installed product before ordering.
Functional Check After Replacement
After fitting the replacement, follow the equipment commissioning procedure before returning the machine to normal operation. Where applicable, test under controlled conditions and observe response, movement, signals, leakage, and connection stability. Check the installation again after its initial run to identify any adjustment that may be needed.
Product Inquiry Support
We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.
Additional information
| Brand | FESTO |
|---|---|
| Model | VSVA-B-T32C-AZH-A2-1R2L |
| Part Number | 534781 |
| Valve function | 2×3/2 closed monostable |
| Type of actuation | Electrical |
| Construction width | 18 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 400 l/min |
| pneumatic working port | Sub-base size 18 mm to ISO 15407-1 Sub-base size 02 to VDMA 24563 |
| Operating voltage | 24 V DC |
| Operating pressure | 3 bar … 10 bar |