FESTO SFAW-100-TG1-E-PNLK-PNVBA-M12 8036877 Flow Sensor
The Festo SFAW-100-TG1-E-PNLK-PNVBA-M12 (part number 8036877) is a flow sensor. Its product datasheet lists operating pressure as 0 MPa … 1.2 MPa and start value for flow rate measuring range as 5 l/min.
Description
FESTO SFAW-100-TG1-E-PNLK-PNVBA-M12 8036877 Flow Sensor
The Festo SFAW-100-TG1-E-PNLK-PNVBA-M12 (part number 8036877) is a flow sensor. Its product datasheet lists operating pressure as 0 MPa … 1.2 MPa and start value for flow rate measuring range as 5 l/min.
Key Features
- Operating pressure: 0 MPa … 1.2 MPa
- Start value for flow rate measuring range: 5 l/min
- End value for flow rate measuring range: 100 l/min
- Note on operating pressure: Max. 1.2 MPa (12 bar / 174 psi) at 40 °C Max. 0.6 MPa (6 bar / 87 psi) at 90 °C
Technical Data
| Brand | FESTO |
|---|---|
| Model | SFAW-100-TG1-E-PNLK-PNVBA-M12 |
| Part number | 8036877 |
| Note on materials | RoHS compliant |
| Measured variable | Flow rate Temperature |
| Flow direction | Unidirectional P1 -> P2 |
| Measurement method | Flow rate: Vortex Temperature: PT1000 |
| Start value for flow rate measuring range | 5 l/min |
| End value for flow rate measuring range | 100 l/min |
| Operating pressure | 0 MPa … 1.2 MPa |
| Operating pressure | 0 bar … 12 bar |
| Operating pressure | 0 psi … 174 psi |
| Note on operating pressure | Max. 1.2 MPa (12 bar / 174 psi) at 40 °C Max. 0.6 MPa (6 bar / 87 psi) at 90 °C |
| Overload pressure | 4 MPa |
| Overload pressure | 40 bar |
| Overload pressure | 580 psi |
| Operating medium | Liquid media Water Neutral fluids |
| Note on operating and pilot medium | Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances in contact with the media must be ensured. |
| Media temperature | 0 °C … 90 °C |
| Ambient temperature | 0 °C … 50 °C |
| Nominal temperature | 23 °C |
| Accuracy of flow rate | ±2 %FS for flow ≤ 50 %FS ±3% of measured value for flow rate ≥ 50% FS |
| Accuracy temperature in ± °C | 2 °C |
| Repetition accuracy of flow rate | < ±0.5% FS for flow rate <= 50 %FS < ±1% of measured value for flow rate >= 50 %FS |
| Temperature coefficient span in ± %FS/K | typ. ±0.05%FS/K |
| Switching output | 2 x PNP or 2 x NPN, switchable |
| Switching function | Window comparator Threshold value comparator Freely programmable |
| Switching element function | NC or NO, switchable |
| Max. output current | 100 mA |
| Analogue output | 0 – 10 V 4 – 20 mA 1 – 5 V |
| Flow characteristic curve start value | 0 l/min |
| Flow characteristic curve end value | 100 l/min |
| Max. load resistance current output | 500 Ohm |
| Min. load resistance voltage output | 15 kOhm |
| Short circuit current rating | Yes |
| Overload protection | Available |
| Protocol | IO-Link® |
| Operational voltage range DC | 18 V … 30 V |
| Reverse polarity protection | For all electrical connections |
| Electrical connection 1, connection type | Plug |
| Electrical connection 1, connector system | M12x1, A-coded to EN 61076-2-101 |
| Electrical connection 1, number of connections/cores | 5 |
| Electrical connection 1, type of mounting | Screw-type lock Not rotatable |
| Electrical connection 1, compatible type of mounting | Compatible with rotatable screw-type lock |
| Electrical connection 1, connection pattern | 00995383 |
| Mounting position | Any |
| Fluid connection | Female thread G1 |
| Product weight | 400 g |
| Material housing | Reinforced PA |
| Material in contact with the medium | EPDM (peroxide) ETFE Stainless steel PA6T/6I reinforced |
| Degree of protection | IP65 |
Application Notes
Check the complete model code, installed connections and operating limits against the original equipment. Products in the same series may differ in size, stroke, actuation, pressure range or mounting details.
Selection and Installation
Compare the original nameplate and part number with the product-specific datasheet. Follow the equipment manufacturer instructions for installation and commissioning, and clarify uncertain options before ordering.
Inquiry
For a quotation or replacement enquiry, provide model SFAW-100-TG1-E-PNLK-PNVBA-M12, part number 8036877, quantity, destination and clear photos of the original unit when available.
Datasheet Selection Note
Festo lists end value for flow rate measuring range as 100 l/min for part number 8036877. Confirm the full model code and the matching connection, operating range and mounting arrangement against the installed product before ordering.
Operating Conditions Check
Before selecting SFAW-100-TG1-E-PNLK-PNVBA-M12, confirm that the actual operating conditions fall within the specifications for the exact version being ordered. Relevant factors may include supply voltage, pressure, temperature, medium, and operating frequency, depending on the product type. Do not apply a series-wide maximum rating to an individual variant without checking its documentation.
International Delivery Options
We can discuss international delivery arrangements according to the order and destination. FedEx, UPS, DHL, or another suitable express service may be considered based on the shipment requirements. Please provide the delivery location and product details during the enquiry so that the available shipping arrangement can be confirmed before the order is processed.
Additional information
| Brand | FESTO |
|---|---|
| Model | SFAW-100-TG1-E-PNLK-PNVBA-M12 |
| Part Number | 8036877 |
| Note on materials | RoHS compliant |
| Measured variable | Flow rate Temperature |
| Flow direction | Unidirectional P1 -> P2 |
| Measurement method | Flow rate: Vortex Temperature: PT1000 |
| Start value for flow rate measuring range | 5 l/min |
| End value for flow rate measuring range | 100 l/min |
| Operating pressure | 0 bar … 12 bar |