FESTO SFAW-32-TG12-E-PNLK-PNVBA-M12 8036871 Flow Sensor

The Festo SFAW-32-TG12-E-PNLK-PNVBA-M12 (part number 8036871) is a flow sensor. Its product datasheet lists operating pressure as 0 MPa … 1.2 MPa and start value for flow rate measuring range as 1.8 l/min.

SKU: 8036871 Category: Tags: , , Brand:

Description

FESTO SFAW-32-TG12-E-PNLK-PNVBA-M12 8036871 Flow Sensor

The Festo SFAW-32-TG12-E-PNLK-PNVBA-M12 (part number 8036871) is a flow sensor. Its product datasheet lists operating pressure as 0 MPa … 1.2 MPa and start value for flow rate measuring range as 1.8 l/min.

Key Features

  • Operating pressure: 0 MPa … 1.2 MPa
  • Start value for flow rate measuring range: 1.8 l/min
  • End value for flow rate measuring range: 32 l/min
  • Note on operating pressure: Max. 1.2 MPa (12 bar / 174 psi) at 40 °C Max. 0.6 MPa (6 bar / 87 psi) at 90 °C

Technical Data

Brand FESTO
Model SFAW-32-TG12-E-PNLK-PNVBA-M12
Part number 8036871
Note on materials RoHS compliant
Measured variable Flow rate
Temperature
Flow direction Unidirectional
P1 -> P2
Measurement method Flow rate: Vortex
Temperature: PT1000
Start value for flow rate measuring range 1.8 l/min
End value for flow rate measuring range 32 l/min
Operating pressure 0 MPa … 1.2 MPa
Operating pressure 0 bar … 12 bar
Operating pressure 0 psi … 174 psi
Note on operating pressure Max. 1.2 MPa (12 bar / 174 psi) at 40 °C
Max. 0.6 MPa (6 bar / 87 psi) at 90 °C
Overload pressure 4 MPa
Overload pressure 40 bar
Overload pressure 580 psi
Operating medium Liquid media
Water
Neutral fluids
Note on operating and pilot medium Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility
of the media with the substances in contact with the media must be
ensured.
Media temperature 0 °C … 90 °C
Ambient temperature 0 °C … 50 °C
Nominal temperature 23 °C
Accuracy of flow rate ±2 %FS for flow ≤ 50 %FS
±3% of measured value for flow rate ≥ 50% FS
Accuracy temperature in ± °C 2 °C
Repetition accuracy of flow rate < ±0.5% FS for flow rate <= 50 %FS
< ±1% of measured value for flow rate >= 50 %FS
Temperature coefficient span in ± %FS/K typ. ±0.05%FS/K
Switching output 2 x PNP or 2 x NPN, switchable
Switching function Window comparator
Threshold value comparator
Freely programmable
Switching element function NC or NO, switchable
Max. output current 100 mA
Analogue output 0 – 10 V
4 – 20 mA
1 – 5 V
Flow characteristic curve start value 0 l/min
Flow characteristic curve end value 32 l/min
Max. load resistance current output 500 Ohm
Min. load resistance voltage output 15 kOhm
Short circuit current rating Yes
Overload protection Available
Protocol IO-Link®
Operational voltage range DC 18 V … 30 V
Reverse polarity protection For all electrical connections
Electrical connection 1, connection type Plug
Electrical connection 1, connector system M12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores 5
Electrical connection 1, type of mounting Screw-type lock
Not rotatable
Electrical connection 1, compatible type of mounting Compatible with rotatable screw-type lock
Electrical connection 1, connection pattern 00995383
Mounting position Any
Fluid connection Female thread G1/2
Product weight 400 g
Material housing Reinforced PA
Material in contact with the medium EPDM (peroxide)
ETFE
Stainless steel
PA6T/6I reinforced
Degree of protection IP65

Application Notes

Check the complete model code, installed connections and operating limits against the original equipment. Products in the same series may differ in size, stroke, actuation, pressure range or mounting details.

Selection and Installation

Compare the original nameplate and part number with the product-specific datasheet. Follow the equipment manufacturer instructions for installation and commissioning, and clarify uncertain options before ordering.

Inquiry

For a quotation or replacement enquiry, provide model SFAW-32-TG12-E-PNLK-PNVBA-M12, part number 8036871, quantity, destination and clear photos of the original unit when available.

Datasheet Selection Note

Festo lists end value for flow rate measuring range as 32 l/min for part number 8036871. Confirm the full model code and the matching connection, operating range and mounting arrangement against the installed product before ordering.

Spare Parts Records

Keeping a clear record of installed components can make future maintenance and purchasing more efficient. For this product, record the brand, full model code, important specifications, and equipment location. Update the record whenever a component or machine configuration changes, so the next replacement decision is based on current information.

Payment Arrangements

The payment method is confirmed as part of the order arrangement. International orders may be settled in USD by T/T, PayPal, or another mutually agreed method. For payments in RMB within mainland China, Alipay QR code and WeChat Pay QR code arrangements are also available. The applicable option is agreed before order processing.

Additional information

Brand

FESTO

Model

SFAW-32-TG12-E-PNLK-PNVBA-M12

Part Number

8036871

Note on materials

RoHS compliant

Measured variable

Flow rate Temperature

Flow direction

Unidirectional P1 -> P2

Measurement method

Flow rate: Vortex Temperature: PT1000

Start value for flow rate measuring range

1.8 l/min

End value for flow rate measuring range

32 l/min

Operating pressure

0 bar … 12 bar