FESTO SFAW-32T-TG12-E-PNLK-PNVBA-M12 8036872 Flow Sensor
The Festo SFAW-32T-TG12-E-PNLK-PNVBA-M12 (part number 8036872) is a flow sensor. Its product datasheet lists operating pressure as 0 MPa … 1.2 MPa and start value for flow rate measuring range as 1.8 l/min.
Description
FESTO SFAW-32T-TG12-E-PNLK-PNVBA-M12 8036872 Flow Sensor
The Festo SFAW-32T-TG12-E-PNLK-PNVBA-M12 (part number 8036872) is a flow sensor. Its product datasheet lists operating pressure as 0 MPa … 1.2 MPa and start value for flow rate measuring range as 1.8 l/min.
Key Features
- Operating pressure: 0 MPa … 1.2 MPa
- Start value for flow rate measuring range: 1.8 l/min
- End value for flow rate measuring range: 32 l/min
- Note on operating pressure: Max. 1.2 MPa (12 bar / 174 psi) at 40 °C Max. 0.6 MPa (6 bar / 87 psi) at 90 °C
Technical Data
| Brand | FESTO |
|---|---|
| Model | SFAW-32T-TG12-E-PNLK-PNVBA-M12 |
| Part number | 8036872 |
| Note on materials | RoHS compliant |
| Measured variable | Flow rate Temperature |
| Flow direction | Unidirectional P1 -> P2 |
| Measurement method | Flow rate: Vortex Temperature: PT1000 |
| Start value for flow rate measuring range | 1.8 l/min |
| End value for flow rate measuring range | 32 l/min |
| Temperature measurement start value | 0 °C |
| Temperature measurement end value | 90 °C |
| Operating pressure | 0 MPa … 1.2 MPa |
| Operating pressure | 0 bar … 12 bar |
| Operating pressure | 0 psi … 174 psi |
| Note on operating pressure | Max. 1.2 MPa (12 bar / 174 psi) at 40 °C Max. 0.6 MPa (6 bar / 87 psi) at 90 °C |
| Overload pressure | 4 MPa |
| Overload pressure | 40 bar |
| Overload pressure | 580 psi |
| Operating medium | Liquid media Water Neutral fluids |
| Note on operating and pilot medium | Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances in contact with the media must be ensured. |
| Media temperature | 0 °C … 90 °C |
| Ambient temperature | 0 °C … 50 °C |
| Nominal temperature | 23 °C |
| Accuracy of flow rate | ±2 %FS for flow ≤ 50 %FS ±3% of measured value for flow rate ≥ 50% FS |
| Accuracy temperature in ± °C | 2 °C |
| Repetition accuracy of flow rate | < ±0.5% FS for flow rate <= 50 %FS < ±1% of measured value for flow rate >= 50 %FS |
| Temperature coefficient span in ± %FS/K | typ. ±0.05%FS/K |
| Switching output | 2 x PNP or 2 x NPN, switchable |
| Switching function | Window comparator Threshold value comparator Freely programmable |
| Switching element function | NC or NO, switchable |
| Max. output current | 100 mA |
| Temperature characteristic curve start value | 0 °C |
| Temperature characteristic curve end value | 100 °C |
| Max. load resistance current output | 500 Ohm |
| Min. load resistance voltage output | 15 kOhm |
| Short circuit current rating | Yes |
| Overload protection | Available |
| Operational voltage range DC | 18 V … 30 V |
| Reverse polarity protection | For all electrical connections |
| Electrical connection 1, connection type | Plug |
| Electrical connection 1, connector system | M12x1, A-coded to EN 61076-2-101 |
| Electrical connection 1, number of connections/cores | 5 |
| Electrical connection 1, type of mounting | Screw-type lock Not rotatable |
| Electrical connection 1, compatible type of mounting | Compatible with rotatable screw-type lock |
| Electrical connection 1, connection pattern | 00995383 |
| Mounting position | Any |
| Fluid connection | Female thread G1/2 |
| Product weight | 400 g |
| Material housing | Reinforced PA |
| Material in contact with the medium | EPDM (peroxide) ETFE Stainless steel PA6T/6I reinforced |
| Degree of protection | IP65 |
Application Notes
Check the complete model code, installed connections and operating limits against the original equipment. Products in the same series may differ in size, stroke, actuation, pressure range or mounting details.
Selection and Installation
Compare the original nameplate and part number with the product-specific datasheet. Follow the equipment manufacturer instructions for installation and commissioning, and clarify uncertain options before ordering.
Inquiry
For a quotation or replacement enquiry, provide model SFAW-32T-TG12-E-PNLK-PNVBA-M12, part number 8036872, quantity, destination and clear photos of the original unit when available.
Datasheet Selection Note
Festo lists end value for flow rate measuring range as 32 l/min for part number 8036872. Confirm the full model code and the matching connection, operating range and mounting arrangement against the installed product before ordering.
Replacement Compatibility
Before ordering FESTO SFAW-32T-TG12-E-PNLK-PNVBA-M12 8036872 Flow Sensor as a replacement, compare the complete model code with the part currently installed. Check the connection style, mounting dimensions, electrical rating, and any series-specific suffixes. Parts that look alike may operate differently, so confirm the relevant specifications against the equipment requirements before treating them as interchangeable.
Order Detail Confirmation
To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.
Additional information
| Brand | FESTO |
|---|---|
| Model | SFAW-32T-TG12-E-PNLK-PNVBA-M12 |
| Part Number | 8036872 |
| Note on materials | RoHS compliant |
| Measured variable | Flow rate Temperature |
| Flow direction | Unidirectional P1 -> P2 |
| Measurement method | Flow rate: Vortex Temperature: PT1000 |
| Start value for flow rate measuring range | 1.8 l/min |
| End value for flow rate measuring range | 32 l/min |
| Temperature measurement start value | 0 °C |
| Temperature measurement end value | 90 °C |