Technical Data

Brand FESTO
Model SOPA-M1-R1-HQ6-2P-M12
Part number 552146
KC mark KC-EMV
Note on materials RoHS compliant
Detected variable Distance
Measuring principle Pneumatic
Sensing range 20 µm … 200 µm
Supply pressure 0.8 bar … 1.6 bar
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot medium Lubricated operation possible (in which case lubricated operation will
always be required)
Ambient temperature 0 °C … 50 °C
Repetition accuracy in ± µm 2.5 µm
Switching output 2xPNP
Switching function Window comparator
Threshold value with variable hysteresis
Switching element function NC or NO, switchable
Max. output current 100 mA
Short circuit current rating Yes
Operational voltage range DC 15 V … 30 V
Max. current consumption 250 mA
Reverse polarity protection For all electrical connections
Electrical connection 1, connection type Plug
Electrical connection 1, connector system M12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores 5
Electrical connection 1, type of mounting Screw-type lock
Not rotatable
Electrical connection 1, compatible type of mounting Compatible with rotatable screw-type lock
Electrical connection 1, connection pattern 00991172
Type of mounting With through-hole
via DIN rail
Pneumatic connection QS-6
Product weight 60 g
Material housing Anodised aluminium
Reinforced PA
Display type Illuminated LCD, multi-colour
Setting options Teach-in
Via display and buttons
Protection against tampering Electronic interlock
Degree of protection IP65
Corrosion resistance class CRC 2 – Moderate corrosion stress

Application Notes

Check the complete model code, installed connections and operating limits against the original equipment. Products in the same series may differ in size, stroke, actuation, pressure range or mounting details.

Selection and Installation

Compare the original nameplate and part number with the product-specific datasheet. Follow the equipment manufacturer instructions for installation and commissioning, and clarify uncertain options before ordering.

Inquiry

For a quotation or replacement enquiry, provide model SOPA-M1-R1-HQ6-2P-M12, part number 552146, quantity, destination and clear photos of the original unit when available.

Datasheet Selection Note

Festo lists ambient temperature as 0 °C … 50 °C for part number 552146. Confirm the full model code and the matching connection, operating range and mounting arrangement against the installed product before ordering.

Spare Parts Records

Keeping a clear record of installed components can make future maintenance and purchasing more efficient. For this product, record the brand, full model code, important specifications, and equipment location. Update the record whenever a component or machine configuration changes, so the next replacement decision is based on current information.

Order Detail Confirmation

To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.

Additional information

Brand

FESTO

Model

SOPA-M1-R1-HQ6-2P-M12

Part Number

552146

KC mark

KC-EMV

Note on materials

RoHS compliant

Detected variable

Distance

Measuring principle

Pneumatic

Sensing range

20 µm … 200 µm

Supply pressure

0.8 bar … 1.6 bar

Operating medium

Compressed air to ISO 8573-1:2010 [7:4:4]

Note on operating and pilot medium

Lubricated operation possible (in which case lubricated operation will always be required)