FESTO CPX-FB38 552046 Bus Node
The Festo CPX-FB38 (part number 552046) is a bus node. Its product datasheet lists operating voltage range dc as 18 … 30 V and ambient temperature as -5 … 50 °C.
Description
FESTO CPX-FB38 552046 Bus Node
The Festo CPX-FB38 (part number 552046) is a bus node. Its product datasheet lists operating voltage range dc as 18 … 30 V and ambient temperature as -5 … 50 °C.
Key Features
- Operating voltage range DC: 18 … 30 V
- Ambient temperature: -5 … 50 °C
- Dimensions W x L x H: (including interlinking block) 50 mm x 107 mm x 50 mm
- Intrinsic current consumption at operating voltage: Typ. 100 mA
Technical Data
| Brand | FESTO |
|---|---|
| Model | CPX-FB38 |
| Part number | 552046 |
| Dimensions W x L x H | (including interlinking block) 50 mm x 107 mm x 50 mm |
| Fieldbus interface | 2x socket, M12x1, 4-pin, D-coded |
| Device-specific diagnostics | Channel and module-orientated diagnostics – Undervoltage of modules – Diagnostic memory |
| Configuration support | XML file |
| Parameters configuring | – Diagnostic behaviour – Failsafe response – Forcing of channels – Signal setup – System parameter |
| Additional functions | System status can be represented using process data Additional diagnostics interface for operator units |
| Control elements | DIL switches |
| Baud rate | 100 MBit/s |
| Operating voltage range DC | 18 … 30 V |
| Intrinsic current consumption at operating voltage | Typ. 100 mA |
| Nominal operating voltage DC | 24 V |
| Corrosion resistance classification CRC | 1 – Low corrosion stress |
| Storage temperature | -20 … 70 °C |
| Protection class | IP65 IP67 |
| Ambient temperature | -5 … 50 °C |
| Product weight | 125 g |
| Maximum address volume for outputs | 64 Byte |
| Maximum address volume for inputs | 64 Byte |
| Protocol | EtherCAT |
| Bus-specific LED display | Error: communication error L/A1: network active, port 1 L/A2: network active, port 2 Run: Communication status |
| Product-specific LED display | M: Modify, parameterisation PL: load supply PS: Electronics supply, sensor supply SF: system error |
| Material housing | PA-reinforced |
Application Notes
Check the complete model code, installed connections and operating limits against the original equipment. Products in the same series may differ in size, stroke, actuation, pressure range or mounting details.
Selection and Installation
Compare the original nameplate and part number with the product-specific datasheet. Follow the equipment manufacturer instructions for installation and commissioning, and clarify uncertain options before ordering.
Inquiry
For a quotation or replacement enquiry, provide model CPX-FB38, part number 552046, quantity, destination and clear photos of the original unit when available.
Datasheet Selection Note
Festo lists dimensions w x l x h as (including interlinking block) 50 mm x 107 mm x 50 mm for part number 552046. Confirm the full model code and the matching connection, operating range and mounting arrangement against the installed product before ordering.
Functional Check After Replacement
After fitting the replacement, follow the equipment commissioning procedure before returning the machine to normal operation. Where applicable, test under controlled conditions and observe response, movement, signals, leakage, and connection stability. Check the installation again after its initial run to identify any adjustment that may be needed.
Product Inquiry Support
We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.
Additional information
| Brand | FESTO |
|---|---|
| Model | CPX-FB38 |
| Part Number | 552046 |
| Dimensions W x L x H | (including interlinking block) 50 mm x 107 mm x 50 mm |
| Fieldbus interface | 2x socket, M12x1, 4-pin, D-coded |
| Device-specific diagnostics | Channel and module-orientated diagnostics – Undervoltage of modules – Diagnostic memory |
| Configuration support | XML file |
| Parameters configuring | – Diagnostic behaviour – Failsafe response – Forcing of channels – Signal setup – System parameter |
| Additional functions | System status can be represented using process data Additional diagnostics interface for operator units |
| Control elements | DIL switches |
| Baud rate | 100 MBit/s |