FESTO CPX-AP-I-PN-M12 8086607 PROFINET Interface
The Festo CPX-AP-I-PN-M12 (part number 8086607) is a profinet interface. Its product datasheet lists type of mounting as On DIN rail via accessories With through-hole and ambient temperature as -20 °C … 60 °C.
Description
FESTO CPX-AP-I-PN-M12 8086607 PROFINET Interface
The Festo CPX-AP-I-PN-M12 (part number 8086607) is a profinet interface. Its product datasheet lists type of mounting as On DIN rail via accessories With through-hole and ambient temperature as -20 °C … 60 °C.
Key Features
- Type of mounting: On DIN rail via accessories With through-hole
- Ambient temperature: -20 °C … 60 °C
- Degree of protection: IP65 IP67
- Note on degree of protection: Unused connections sealed
Technical Data
| Brand | FESTO |
|---|---|
| Model | CPX-AP-I-PN-M12 |
| Part number | 8086607 |
| Dimensions (W x L x H) | 45 mm x 170 mm x 35 mm |
| Type of mounting | On DIN rail via accessories With through-hole |
| Max. number of modules | 80 |
| Product weight | 186 g |
| Ambient temperature | -20 °C … 60 °C |
| Storage temperature | -40 °C … 70 °C |
| Relative air humidity | 5 – 95% Non-condensing |
| Degree of protection | IP65 IP67 |
| Note on degree of protection | Unused connections sealed |
| Corrosion resistance class CRC | 1 – Low corrosion stress |
| Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
| Max. cable length | 50 m system communication |
| Note on max. cable length | Power supply according to nominal voltage |
| Cleanroom suitability, measured according to ISO 14644-14 | Element installed statically, no meaningful evaluation possible according to ISO 14644-1 |
| KC mark | KC-EMV |
| Note on materials | RoHS compliant |
| Material housing | Makrolon® Nickel-plated die-cast zinc |
| Material o-ring | Fluoro rubber |
| Diagnostics via LED | Diagnostics per module Network error Power supply, electronics/sensors Load power supply System diagnostics Maintenance required |
| Diagnostics via bus | Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage |
| Diagnostics per internal communication | Module error Output short circuit/overload Short circuit/overload in sensor supply Load supply undervoltage |
| Fieldbus interface | Ethernet |
| Field bus, protocol | PROFINET IRT PROFINET RT |
| Fieldbus interface, function | Bus connection incoming/outgoing |
| Field bus, connection type | 2x socket |
| Field bus, connection system | M12x1, D-coded to EN 61076-2-101 |
| Field bus, connection pattern | 4 |
| Field bus interface, electrical isolation | Yes |
| Field bus interface, transmission rate | 100 Mbit/s |
| Max. address volume, inputs | 1024 Byte |
| Max. address volume, outputs | 1024 Byte |
| Configuration support | GSDML file |
| Communication interface, connection type | 2x socket |
| Communication interface, connection technology | M8x1, D-coded according to EN 61076-2-114 |
| Power supply, connection type | Plug |
| power supply, connection system | M8x1, A-coded to EN 61076-2-104 |
| Power supply, connection pattern | 00991171 |
| Power transmission, connection type | Socket |
| Power transmission, connection technology | M8x1, A-coded to EN 61076-2-104 |
| Note regarding operating voltage | SELV/PELV fixed power supplies required Note the voltage drop |
| Nominal operating voltage DC of load | 24 V |
| Permissible voltage fluctuation of load | ±25% |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ±25% |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 80 mA |
| Intrinsic current consumption at nominal operating voltage load | Typically 5 mA |
| Reverse polarity protection | Yes |
Application Notes
Check the complete model code, installed connections and operating limits against the original equipment. Products in the same series may differ in size, stroke, actuation, pressure range or mounting details.
Selection and Installation
Compare the original nameplate and part number with the product-specific datasheet. Follow the equipment manufacturer instructions for installation and commissioning, and clarify uncertain options before ordering.
Inquiry
For a quotation or replacement enquiry, provide model CPX-AP-I-PN-M12, part number 8086607, quantity, destination and clear photos of the original unit when available.
Datasheet Selection Note
Festo lists degree of protection as IP65 IP67 for part number 8086607. Confirm the full model code and the matching connection, operating range and mounting arrangement against the installed product before ordering.
Spare Parts Records
Keeping a clear record of installed components can make future maintenance and purchasing more efficient. For this product, record the brand, full model code, important specifications, and equipment location. Update the record whenever a component or machine configuration changes, so the next replacement decision is based on current information.
Product Inquiry Support
We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.
Additional information
| Brand | FESTO |
|---|---|
| Model | CPX-AP-I-PN-M12 |
| Part Number | 8086607 |
| Dimensions (W x L x H) | 45 mm x 170 mm x 35 mm |
| Type of mounting | On DIN rail via accessories With through-hole |
| Max. number of modules | 80 |
| Product weight | 186 g |
| Ambient temperature | -20 °C … 60 °C |
| Storage temperature | -40 °C … 70 °C |
| Relative air humidity | 5 – 95% Non-condensing |
| Degree of protection | IP65 IP67 |