FESTO MFH-5/2-D-1-C 150981 Solenoid Valve
The FESTO MFH-5/2-D-1-C, part number 150981, is a solenoid valve. Its exact-model datasheet lists valve function as 5/2-way, single solenoid and pneumatic working port as Sub-base size 1 to ISO 5599-1 G1/4.
Description
FESTO MFH-5/2-D-1-C 150981 Solenoid Valve
The FESTO MFH-5/2-D-1-C, part number 150981, is a solenoid valve. Its exact-model datasheet lists valve function as 5/2-way, single solenoid and pneumatic working port as Sub-base size 1 to ISO 5599-1 G1/4.
Key Features
- Valve function: 5/2-way, single solenoid.
- pneumatic working port: Sub-base size 1 to ISO 5599-1 G1/4.
- Operating voltage: Via solenoid coil, must be ordered separately.
Technical Data
| Brand | FESTO |
|---|---|
| Model | MFH-5/2-D-1-C |
| Part number | 150981 |
| Product type | Solenoid Valve |
| Valve function | 5/2-way, single solenoid |
| Type of actuation | Electrical |
| Construction width | 42 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 1200 l/min |
| pneumatic working port | Sub-base size 1 to ISO 5599-1 G1/4 |
| Operating voltage | Via solenoid coil, must be ordered separately |
| Operating pressure | 0.2 MPa … 1 MPa |
| Operating pressure | 2 bar … 10 bar |
| Design | Piston gate valve |
| Type of reset | Pneumatic spring |
| Degree of protection | IP65 |
| Nominal size | 8 mm |
| Grid dimension | 43 mm |
| Exhaust-air function | Can be throttled |
| Sealing principle | Soft |
| Mounting position | Any |
| Conforms to standard | ISO 5599-1 |
| Manual override | Detenting via accessory Non-detenting |
| ISO code | 151 |
| Type of piloting | Piloted |
| Pilot air supply | Internal |
| Flow direction | Non-reversible |
| lap | Overlap |
| Suitability for vacuum | No |
| Switching time off | 35 ms |
| Switching time on | 23 ms |
| Max. positive test pulse with 0 signal | 2200 µs |
| Max. negative test pulse with 1 signal | 3700 µs |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) |
| Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Media temperature | -10 °C … 60 °C |
| Sound pressure level | 85 dB(A) |
| Pilot medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Ambient temperature | -5 °C … 40 °C |
| Product weight | 390 g |
| Electrical connection | 3-pin Type A, with VACF-A coil Type B industry (11 mm), with MSF coil Via solenoid coil, to be ordered separately |
| Type of mounting | On sub-base With through-hole |
| Pilot exhaust port 84 | M5 |
| Pilot air port 12 | Sub-base size 1 to ISO 5599-1 |
| Pilot air port 14 | Sub-base size 1 to ISO 5599-1 |
| Pneumatic connection, port 1 | Sub-base size 1 to ISO 5599-1 |
| Pneumatic connection, port 2 | Sub-base size 1 to ISO 5599-1 |
| Pneumatic connection, port 3 | Sub-base size 1 to ISO 5599-1 |
| Pneumatic connection, port 4 | Sub-base size 1 to ISO 5599-1 |
| Pneumatic connection, port 5 | Sub-base size 1 to ISO 5599-1 |
| Material seals | HNBR NBR |
| Material housing | Die-cast aluminium |
Application Notes
Check the complete model and part number against the original equipment. Items in the same series may differ in dimensions, connection type or operating configuration.
Selection and Installation
Confirm the selected variant and installation requirements with the equipment documentation. Follow the manufacturer instructions for service and commissioning.
Inquiry
For a quotation, provide model MFH-5/2-D-1-C, part number 150981, quantity and destination. Clear photos of the existing item or package can help confirm the selection.
Exact-Model Datasheet Check
The Festo datasheet for MFH-5/2-D-1-C, part number 150981, lists valve function as 5/2-way, single solenoid and pneumatic working port as Sub-base size 1 to ISO 5599-1 G1/4. Compare the full designation and connection details with the installed item before ordering.
Functional Check After Replacement
After fitting the replacement, follow the equipment commissioning procedure before returning the machine to normal operation. Where applicable, test under controlled conditions and observe response, movement, signals, leakage, and connection stability. Check the installation again after its initial run to identify any adjustment that may be needed.
Product Inquiry Support
We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.
Additional information
| Brand | FESTO |
|---|---|
| Model | MFH-5/2-D-1-C |
| Part Number | 150981 |
| Product Type | Solenoid Valve |
| Valve function | 5/2-way, single solenoid |
| Type of actuation | Electrical |
| Construction width | 42 mm |
| Standard nominal flow rate (standardised to DIN 1343) | 1200 l/min |
| pneumatic working port | Sub-base size 1 to ISO 5599-1 G1/4 |
| Operating voltage | Via solenoid coil, must be ordered separately |
| Operating pressure | 2 bar … 10 bar |