FESTO GRLA-1/8-QS-8-RS-B 162966 One-Way Flow Control Valve
The FESTO GRLA-1/8-QS-8-RS-B, part number 162966, is a one-way flow control valve. The supplied Festo datasheet confirms this product identity and lists its model-specific technical data below.
Description
FESTO GRLA-1/8-QS-8-RS-B 162966 One-Way Flow Control Valve
The FESTO GRLA-1/8-QS-8-RS-B, part number 162966, is a one-way flow control valve. The supplied Festo datasheet confirms this product identity and lists its model-specific technical data below.
Key Features
- Valve function: One-way flow control function for exhaust air.
- Pneumatic connection, port 1: QS-8.
- Pneumatic connection, port 2: G1/8.
Technical Data
| Brand | FESTO |
|---|---|
| Model | GRLA-1/8-QS-8-RS-B |
| Part number | 162966 |
| Product type | One-Way Flow Control Valve |
| Valve function | One-way flow control function for exhaust air |
| Pneumatic connection, port 1 | QS-8 |
| Pneumatic connection, port 2 | G1/8 |
| Type of actuation | manual |
| Adjusting element | Knurled screw |
| Mounting type | Threaded |
| Standard nominal flow rate in flow control direction | 650 l/min |
| Standard nominal flow rate in non-return direction | 600 … 750 l/min |
| Ambient temperature | -10 … 60 °C |
| Assembly position | Any |
| Operating pressure complete temperature range | 0.2 … 10 bar |
| Standard flow rate in flow control direction 0.6->0 MPa (6->0 bar, 87->0 psi) | 1,080 l/min |
| Standard flow rate in non-return direction at 0.6->0 MPa (6->0 bar, 87->0 psi) | 800 … 1250 l/min |
| Operating medium | Compressed air in accordance with ISO8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (subsequently required for further operation) |
| Storage temperature | -10 … 40 °C |
| Medium temperature | -10 … 60 °C |
| Nominal tightening torque | 3.5 Nm |
| Tolerance for nominal tightening torque | ± 20 % |
| Permissible actuation moment, regulating screw | 0.4 Nm |
| Product weight | 25 g |
| Material of threaded plug | Wrought Aluminium alloy |
| Material seals | NBR TPE-U(PU) |
| Material release ring | POM |
| Material knurled head | Wrought Aluminium alloy |
| Material adjusting screw | Brass |
| Material swivel fitting | PBT-reinforced |
Application Notes
Confirm the complete model and part number against the existing equipment. Products in the same Festo series may have different dimensions, connections and operating configurations.
Selection and Installation
Check the equipment documentation and the applicable Festo installation instructions before replacement or commissioning.
Inquiry
For a quotation, provide model GRLA-1/8-QS-8-RS-B, part number 162966, required quantity and destination.
Exact-Model Datasheet Check
The supplied Festo datasheet identifies GRLA-1/8-QS-8-RS-B as a one-way flow control valve under part number 162966. It lists valve function as One-way flow control function for exhaust air. Confirm the full variant before ordering.
Functional Check After Replacement
After fitting the replacement, follow the equipment commissioning procedure before returning the machine to normal operation. Where applicable, test under controlled conditions and observe response, movement, signals, leakage, and connection stability. Check the installation again after its initial run to identify any adjustment that may be needed.
Payment Arrangements
The payment method is confirmed as part of the order arrangement. International orders may be settled in USD by T/T, PayPal, or another mutually agreed method. For payments in RMB within mainland China, Alipay QR code and WeChat Pay QR code arrangements are also available. The applicable option is agreed before order processing.
Additional information
| Brand | FESTO |
|---|---|
| Model | GRLA-1/8-QS-8-RS-B |
| Part number | 162966 |
| Product type | One-Way Flow Control Valve |
| Valve function | One-way flow control function for exhaust air |
| Pneumatic connection, port 1 | QS-8 |
| Pneumatic connection, port 2 | G1/8 |
| Type of actuation | manual |
| Adjusting element | Knurled screw |
| Mounting type | Threaded |
| Standard nominal flow rate in flow control direction | 650 l/min |
| Standard nominal flow rate in non-return direction | 600 … 750 l/min |