FESTO CMMP-AS-C2-3A 550041 Motor Controller
The Festo CMMP-AS-C2-3A is a motor controller for servo motors. Its datasheet lists a single-phase 230 V AC nominal operating supply, 2.5 A nominal output current, and 500 VA nominal controller power.
Description
FESTO CMMP-AS-C2-3A 550041 Motor Controller
The Festo CMMP-AS-C2-3A is a motor controller for servo motors. Its datasheet lists a single-phase 230 V AC nominal operating supply, 2.5 A nominal output current, and 500 VA nominal controller power.
Key Features
- Single-phase 230 V AC nominal operating voltage
- 2.5 A nominal output current
- 500 VA nominal controller power
- 24 V DC nominal logic power supply
Technical Data
| Brand | FESTO |
|---|---|
| Model | CMMP-AS-C2-3A |
| Part number | 550041 |
| Active PFC | Yes |
| Mains filter | Integrated |
| Safety function | Safe Torque off (STO) |
| Safety Integrity Level (SIL) | Safe torque off (STO)/SIL 2 |
| Performance level (PL) | Safe torque off (STO)/category 3, performance level d |
| Display | Seven-segment display |
| Output frequency | 0 … 1,000 Hz |
| Output voltage range AC | 0 – 270 V |
| Braking resistance | 165 Ohm |
| Braking resistance pulse power | 1.1 kVA |
| Max. current, digital logic outputs | 100 mA |
| Max. peak current duration | 5 s |
| Max. intermediate circuit voltage, DC | 380 V |
| Nominal output current | 2.5 A |
| Nominal operating voltage, AC | 230 V |
| Nominal controller power | 500 VA |
| Nominal DC voltage, logic power supply | 24 V |
| Nominal current | 2 … 3 A |
| Line frequency | 50 … 60 Hz |
| Parameters configuring interface | Parameters configuration and commissioning Control interface (PtP) RS232 (9600…115000 Bits/s) |
| Nominal operating voltage, phases | Single-phase |
| Peak power | 1,000 VA |
| Effective peak current per phase | 5 A |
| Current consumption, logic power supply without clamping brake | 0.55 A |
| Storage temperature | -25 … 70 °C |
| Relative air humidity | 0 – 90 % |
| Protection class | IP20 |
| Ambient temperature | 0 … 50 °C |
| Product weight | 2,000 g |
| Number of analogue monitor outputs | 2 |
| Number of analogue setpoint inputs | 3 |
| Number of 24 V DC digital logic outputs | 5 |
| Number of digital logic inputs | 10 |
| Communications profile | DS301/DSP402 FHPP |
| Process interface | I/O coupling For 255 positioning records |
| Encoder interface output, characteristics | Resolution 16384 ppr |
| Encoder interface input, characteristics | RS422 EnDat 2.2 |
| Encoder interface output, function | Actual value feedback via encoder signals in speed control mode Setpoint specification for downstream slave drive unit |
| Encoder interface input, function | Encoder signal, speed setpoint in RPM In synchronous operation as specified speed in RPM for the slave drive unit Setpoint position value as encoder signal |
| Fieldbus coupling | CANopen DeviceNet Ethernet Profibus DP Sercos |
| Max. fieldbus transmission speed | 1 Mbit/s |
| Mounting type | on mounting plate Tightened |
Application Notes
Use this exact model only after confirming the complete part number, electrical supply, installed interfaces and environmental limits against the equipment documentation. Similar series members may have different ratings or communication options.
Selection and Installation
Compare the original nameplate and connection layout with the datasheet for this part number. Follow Festo and machine manufacturer instructions for wiring, mounting and commissioning. Confirm any uncertain option or suffix before energising the equipment.
Inquiry
For a quotation or replacement enquiry, provide model CMMP-AS-C2-3A, part number 550041, quantity, destination and clear photos of the installed unit where available.
Single-Phase Supply
Festo specifies a single-phase 230 V AC nominal operating voltage for the CMMP-AS-C2-3A, alongside a 24 V DC nominal logic supply. Verify supply phases and voltage before substituting another CMMP-AS controller.
Installation Preparation
Prepare the equipment according to the site procedure and the manufacturer's instructions before installing this part. Where relevant, isolate power and pressure sources, then check the mounting direction, connection points, and sealing arrangement. After installation, inspect the completed connections before beginning a controlled functional test.
Payment Arrangements
The payment method is confirmed as part of the order arrangement. International orders may be settled in USD by T/T, PayPal, or another mutually agreed method. For payments in RMB within mainland China, Alipay QR code and WeChat Pay QR code arrangements are also available. The applicable option is agreed before order processing.
Additional information
| Brand | FESTO |
|---|---|
| Model | CMMP-AS-C2-3A |
| Part Number | 550041 |
| Active PFC | Yes |
| Mains filter | Integrated |
| Safety function | Safe Torque off (STO) |
| Safety Integrity Level (SIL) | Safe torque off (STO)/SIL 2 |
| Performance level (PL) | Safe torque off (STO)/category 3, performance level d |
| Display | Seven-segment display |
| Output frequency | 0 … 1,000 Hz |
| Output voltage range AC | 0 – 270 V |