FESTO CMMT-AS-C5-11A-P3-MP-S1 8143167 Servo Drive
The Festo CMMT-AS-C5-11A-P3-MP-S1 is a servo drive with a three-phase 400 V AC nominal supply. Its datasheet lists 5 A effective nominal current per phase and a 24 V DC logic supply.
Description
FESTO CMMT-AS-C5-11A-P3-MP-S1 8143167 Servo Drive
The Festo CMMT-AS-C5-11A-P3-MP-S1 is a servo drive with a three-phase 400 V AC nominal supply. Its datasheet lists 5 A effective nominal current per phase and a 24 V DC logic supply.
Key Features
- Three-phase 400 V AC nominal supply
- 5 A effective nominal current per phase
- 24 V DC logic supply
- Multi-protocol fieldbus information in the datasheet
Technical Data
| Brand | FESTO |
|---|---|
| Model | CMMT-AS-C5-11A-P3-MP-S1 |
| Part number | 8143167 |
| Type of mounting | Mounting plate, attached with screws |
| Mounting position | Open convection Vertical |
| Product weight | 2200 g |
| Display | Green/yellow/red LED |
| Storage temperature | -25 °C … 55 °C |
| Ambient temperature | 0 °C … 50 °C |
| Note on ambient temperature | Power must be reduced by 3% per °C at ambient temperatures above 40°C. |
| UL ambient temperature | 0 °C … 50 °C |
| Relative air humidity | 5 – 90% Non-condensing |
| Degree of protection | IP20 |
| Phases of nominal operating voltage | 3 Phase ~ |
| Nominal operating voltage AC | 400 V |
| Input voltage range AC | 200 V … 480 V |
| Nominal current, load supply | 6 A |
| Peak current load power supply | 18 A |
| Nominal voltage load voltage DC | 560 V |
| Nominal voltage for logic power supply DC | 24 V |
| Current consumption of logic power supply without clamping brake | 0.5 A |
| Max. current consumption, logic power supply with clamping brake and I/O | 2.5 A |
| Output voltage class AC | 3x (0 – input) V |
| Nominal current per phase, effective | 5 A |
| Peak current per phase, effective | 15 A |
| Max. peak current duration | 2 s |
| Controller nominal output | 2500 VA |
| Maximum output | 7500 VA |
| Number of inputs for motor temperature sensor | 1 |
| Ethernet interface, function | Parameterisation and commissioning |
| Ethernet interface, protocol | TCP/IP |
| Field bus, protocol | EtherCAT® EtherNet/IP Modbus/TCP PROFINET IRT PROFINET RT |
| Fieldbus interface, function | Bus connection incoming/outgoing EtherCAT® slave PROFINET slave EtherNet/IP slave |
| Fieldbus link | EtherCAT® EtherNet/IP Modbus/TCP PROFINET |
| Communication profile | CiA402 CoE (CANopen over EtherCAT) EoE (Ethernet over EtherCAT) FoE (File over EtherCAT) PROFIdrive DriveProfile |
| Process interfacing | AC1: Adjustable-speed drives AC3: Drives with positioning function AC4: Synchronous servo application Adjustable-speed drives Drives with positioning function I/O mode for 256 positioning records Interpolated mode CSP Interpolated mode CST Interpolated mode CSV |
| Field bus interface, transmission rate | 100 Mbit/s |
| Field bus, connection type | 2x socket |
| Field bus, connection system | RJ45 |
| Encoder interface, function | BiSS-C EnDat® 2.1 encoder EnDat® 2.2-sensor Hiperface encoder Incremental encoder Nikon SIN/COS encoder |
| Encoder interface 2, function | Incremental encoder SIN/COS encoder |
| Encoder interface output, features | 1 MHz maximum output frequency max. 16384 ppr |
| Encoder interface input, features | 1 MHz maximum output frequency max. 16384 ppr |
| Number of digital logic inputs | 12 |
| Number of high-speed logic inputs | 2 |
| Number of digital logic outputs 24 V DC | 6 |
| Number of high-speed switching outputs | 2 |
| Number of floating switching outputs | 1 |
| Number of analogue setpoint inputs | 1 |
| Safety function | Safe brake control (SBC) Safe torque off (STO) Safe Stop 1 (SS1) |
| Performance Level (PL) | Safe brake control (SBC)/category 3, performance level e Safe Torque Off (STO)/category 4, performance level e |
| Number of safe 2-pin inputs | 2 |
| Number of diagnostic outputs | 2 |
Application Notes
Confirm the complete model code, the installed mechanical or electrical interface and the operating limits against the original equipment. Similar products within a series can differ in pressure, supply, output, mounting or communication.
Selection and Installation
Compare the original nameplate, the part number and the product-specific datasheet. Follow Festo and machine manufacturer instructions for mounting, connections and controlled commissioning. Clarify any uncertain option or suffix before ordering.
Inquiry
For a quotation or replacement enquiry, provide model CMMT-AS-C5-11A-P3-MP-S1, part number 8143167, quantity, destination and clear photos of the original unit when available.
C5 Power Rating
Festo specifies 5 A effective nominal current per phase and 2,500 VA nominal controller output for this C5-11A-P3-MP-S1 drive. Verify the exact suffix and connected motor requirements.
Maintenance Inspection
Before replacing CMMT-AS-C5-11A-P3-MP-S1, examine the existing installation for issues that may affect the new part. Check the original label, ports, seals, fittings, cables, and mounting points as applicable. Finding a leak, worn connection, or loose contact before installation can help avoid repeating the same problem after replacement.
Payment Arrangements
The payment method is confirmed as part of the order arrangement. International orders may be settled in USD by T/T, PayPal, or another mutually agreed method. For payments in RMB within mainland China, Alipay QR code and WeChat Pay QR code arrangements are also available. The applicable option is agreed before order processing.
Additional information
| Brand | FESTO |
|---|---|
| Model | CMMT-AS-C5-11A-P3-MP-S1 |
| Part Number | 8143167 |
| Type of mounting | Mounting plate, attached with screws |
| Mounting position | Open convection Vertical |
| Product weight | 2200 g |
| Display | Green/yellow/red LED |
| Storage temperature | -25 °C … 55 °C |
| Ambient temperature | 0 °C … 50 °C |
| Note on ambient temperature | Power must be reduced by 3% per °C at ambient temperatures above 40°C. |
| UL ambient temperature | 0 °C … 50 °C |