FESTO CMMT-AS-C5-11A-P3-PN-S1 5340818 Servo Drive

The Festo CMMT-AS-C5-11A-P3-PN-S1 is a servo drive with a three-phase 400 V AC nominal supply. The datasheet lists 5 A effective nominal current per phase and a PROFINET fieldbus interface.

SKU: 5340818 Category: Tags: , , Brand:

Description

FESTO CMMT-AS-C5-11A-P3-PN-S1 5340818 Servo Drive

The Festo CMMT-AS-C5-11A-P3-PN-S1 is a servo drive with a three-phase 400 V AC nominal supply. The datasheet lists 5 A effective nominal current per phase and a PROFINET fieldbus interface.

Key Features

  • Three-phase 400 V AC nominal supply
  • 5 A effective nominal current per phase
  • PROFINET fieldbus interface
  • 24 V DC nominal logic supply

Technical Data

Brand FESTO
Model CMMT-AS-C5-11A-P3-PN-S1
Part number 5340818
Mounting type Mounting plate, bolted
Product weight 2,200 g
Display LED green/yellow/red
Storage temperature -25 … 55 °C
Ambient temperature 0 … 50 °C
Note on ambient temperature Power must be reduced by 3%/°C at ambient temperatures above 40°C.
UL ambient temperature 0 … 40 °C
Relative air humidity 5 – 90 %
non-condensing
Protection class IP20
Overvoltage category III
Nominal operating voltage, phases Three-phase
Nominal operating voltage, AC 400 V
Permissible voltage fluctuation +/- 10 %
Input voltage range AC 200 … 480 V
Line frequency 48 … 62 Hz
Nominal current, load supply 6 A
Peak current, load supply 18 A
Nominal voltage, load supply DC 560 V
Permissible range, load supply ± 10 %
Nominal DC voltage, logic power supply 24 V
Current consumption, logic power supply without clamping brake 0.5 A
Output voltage range AC 3x (0 – Input) V
Effective nominal current per phase 5 A
Effective peak current per phase 15 A
Max. peak current duration 2 s
Nominal controller power 2,500 W
Number of inputs for motor temperature sensor 1
Ethernet interface, function Parameterisation and commissioning
Ethernet interface, protocol TCP/IP
Fieldbus interface, protocol PROFINET IRT
PROFINET RT
Fieldbus coupling PROFINET
Communications profile PROFIdrive
Process interface AC1: Adj.-Speed Drives
AC3: Drive w. Positioning Func
AC4: Synchr. Servo Application
Fieldbus interface, transmission rate 100 Mbit/s
Fieldbus interface, type of connection 2x socket
Fieldbus interface, connection technology RJ45
Encoder interface, function ENDAT 2.1 encoder
ENDAT 2.2 encoder
Hiperface encoder
Incremental encoder
Nikon
SIN/COS encoder
Encoder interface 2, function Incremental encoder
SIN/COS encoder
Encoder interface output, characteristics 1 MHz maximum output frequency
max. 16384 ppr
Encoder interface input, characteristics 1 MHz maximum output frequency
max. 16384 ppr
Number of digital logic inputs 12
Number of high-speed logic inputs 2
Number of 24 V DC digital logic outputs 6
Number of high-speed switching outputs 2
Number of floating switching outputs 1
Number of analogue setpoint inputs 1
Safety function Safe brake control (SBC)
Safe torque off (STO)
Safe stop 1 (SS1)
Performance level (PL) Safe brake control (SBC) / category 3, Performance Level e
Safe Torque off (STO)/Category 4, Performance Level e
Number of safe 2-pin inputs 2
Number of diagnostic outputs 2

Application Notes

Confirm the complete model code, the installed mechanical or electrical interface and the operating limits against the original equipment. Similar products within a series can differ in pressure, supply, output, mounting or communication.

Selection and Installation

Compare the original nameplate, the part number and the product-specific datasheet. Follow Festo and machine manufacturer instructions for mounting, connections and controlled commissioning. Clarify any uncertain option or suffix before ordering.

Inquiry

For a quotation or replacement enquiry, provide model CMMT-AS-C5-11A-P3-PN-S1, part number 5340818, quantity, destination and clear photos of the original unit when available.

PROFINET Interface

The PN-S1 datasheet lists PROFINET IRT and PROFINET RT as fieldbus protocols, with two RJ45 sockets and 100 Mbit/s transmission. Confirm the installed network and full controller suffix before replacement.

Installation Preparation

Prepare the equipment according to the site procedure and the manufacturer's instructions before installing this part. Where relevant, isolate power and pressure sources, then check the mounting direction, connection points, and sealing arrangement. After installation, inspect the completed connections before beginning a controlled functional test.

Order Detail Confirmation

To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.

Additional information

Brand

FESTO

Model

CMMT-AS-C5-11A-P3-PN-S1

Part Number

5340818

Mounting type

Mounting plate, bolted

Product weight

2,200 g

Display

LED green/yellow/red

Storage temperature

-25 … 55 °C

Ambient temperature

0 … 50 °C

Note on ambient temperature

Power must be reduced by 3%/°C at ambient temperatures above 40°C.

UL ambient temperature

0 … 40 °C

Relative air humidity

5 – 90 % non-condensing