FESTO CPX-AP-I-8DI-M8-3P 8086600 Digital Input Module

The Festo CPX-AP-I-8DI-M8-3P (part number 8086600) is a digital input module. Its product datasheet lists type of mounting as On DIN rail via accessories With through-hole and ambient temperature as -20 °C … 60 °C.

SKU: 8086600 Category: Tags: , , Brand:

Description

FESTO CPX-AP-I-8DI-M8-3P 8086600 Digital Input Module

The Festo CPX-AP-I-8DI-M8-3P (part number 8086600) is a digital input module. Its product datasheet lists type of mounting as On DIN rail via accessories With through-hole and ambient temperature as -20 °C … 60 °C.

Key Features

  • Type of mounting: On DIN rail via accessories With through-hole
  • Ambient temperature: -20 °C … 60 °C
  • Degree of protection: IP65 IP67
  • Note on degree of protection: Unused connections sealed

Technical Data

Brand FESTO
Model CPX-AP-I-8DI-M8-3P
Part number 8086600
Dimensions (W x L x H) 30 mm x 170 mm x 35 mm
Type of mounting On DIN rail via accessories
With through-hole
Product weight 126 g
Ambient temperature -20 °C … 60 °C
Storage temperature -40 °C … 70 °C
Relative air humidity 5 – 95%
Non-condensing
Degree of protection IP65
IP67
Note on degree of protection Unused connections sealed
Corrosion resistance class CRC 1 – Low corrosion stress
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN
60068-2-6
Shock resistance Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Overvoltage category II
Max. cable length 30 m inputs
50 m system communication
Note on max. cable length Power supply according to nominal voltage
Cleanroom suitability, measured according to ISO 14644-14 Element installed statically, no meaningful evaluation possible
according to ISO 14644-1
KC mark KC-EMV
Note on materials RoHS compliant
Material housing Makrolon®
Nickel-plated die-cast zinc
Material o-ring Fluoro rubber
Diagnostics via LED Diagnostics per module
Status per channel
Diagnostics per internal communication Short circuit/overload in sensor supply
Electronics/sensors overvoltage
Electronics/sensors undervoltage
Communication interface, function System communication XF10 IN / XF20 OUT
Communication interface, connection type 2x socket
Communication interface, connection technology M8x1, D-coded according to EN 61076-2-114
Communication interface, plug pattern 00995937
Communication interface, number of pins/cores 4
Communication interface, protocol AP
Communication interface, screened Yes
Power supply, function Incoming electronics/sensors and load
Power supply, connection type Plug
power supply, connection system M8x1, A-coded to EN 61076-2-104
Power supply, connection pattern 00991171
Power supply, number of pins/wires 4
Power transmission, function Outgoing electronics/sensors and load
Power transmission, connection type Socket
Power transmission, connection technology M8x1, A-coded to EN 61076-2-104
Note regarding operating voltage SELV/PELV fixed power supplies required
Note the voltage drop
Nominal DC operating voltage, electronics/sensors 24 V
Permissible voltage fluctuations for electronics/sensors ±25%
Intrinsic current consumption at nominal operating voltage for electronics/sensors Typically 32 mA
Reverse polarity protection Yes
Electrical connection input, function Digital input
Electrical connection input, connection type 8x socket
Electrical connection input, connector system M8x1, A-coded to EN 61076-2-104
Electrical connection input, connection pattern 00991871
Electrical connection input, number of connections/cores 3
Fuse protection of inputs (short circuit) Internal electronic fuse per module
Max. residual current of inputs per module 1.8 A

Application Notes

Check the complete model code, installed connections and operating limits against the original equipment. Products in the same series may differ in size, stroke, actuation, pressure range or mounting details.

Selection and Installation

Compare the original nameplate and part number with the product-specific datasheet. Follow the equipment manufacturer instructions for installation and commissioning, and clarify uncertain options before ordering.

Inquiry

For a quotation or replacement enquiry, provide model CPX-AP-I-8DI-M8-3P, part number 8086600, quantity, destination and clear photos of the original unit when available.

Datasheet Selection Note

Festo lists degree of protection as IP65 IP67 for part number 8086600. Confirm the full model code and the matching connection, operating range and mounting arrangement against the installed product before ordering.

Application Review

When considering this digital input module for an industrial application, review the operating conditions of the equipment rather than relying on the product name alone. Confirm the required connections, available space, duty pattern, and surrounding environment. The final selection should follow the complete product specification and the machine manufacturer's requirements.

International Delivery Options

We can discuss international delivery arrangements according to the order and destination. FedEx, UPS, DHL, or another suitable express service may be considered based on the shipment requirements. Please provide the delivery location and product details during the enquiry so that the available shipping arrangement can be confirmed before the order is processed.

Additional information

Brand

FESTO

Model

CPX-AP-I-8DI-M8-3P

Part Number

8086600

Dimensions (W x L x H)

30 mm x 170 mm x 35 mm

Type of mounting

On DIN rail via accessories With through-hole

Product weight

126 g

Ambient temperature

-20 °C … 60 °C

Storage temperature

-40 °C … 70 °C

Relative air humidity

5 – 95% Non-condensing

Degree of protection

IP65 IP67

Note on degree of protection