The Festo CPX-AP-I-PN-M12 (part number 8086607) is a profinet interface. Its product datasheet lists type of mounting as On DIN rail via accessories With through-hole and ambient temperature as -20 °C … 60 °C.

SKU: 8086607 Category: Tags: , , Brand:

Description

FESTO CPX-AP-I-PN-M12 8086607 PROFINET Interface

The Festo CPX-AP-I-PN-M12 (part number 8086607) is a profinet interface. Its product datasheet lists type of mounting as On DIN rail via accessories With through-hole and ambient temperature as -20 °C … 60 °C.

Key Features

  • Type of mounting: On DIN rail via accessories With through-hole
  • Ambient temperature: -20 °C … 60 °C
  • Degree of protection: IP65 IP67
  • Note on degree of protection: Unused connections sealed

Technical Data

Brand FESTO
Model CPX-AP-I-PN-M12
Part number 8086607
Dimensions (W x L x H) 45 mm x 170 mm x 35 mm
Type of mounting On DIN rail via accessories
With through-hole
Max. number of modules 80
Product weight 186 g
Ambient temperature -20 °C … 60 °C
Storage temperature -40 °C … 70 °C
Relative air humidity 5 – 95%
Non-condensing
Degree of protection IP65
IP67
Note on degree of protection Unused connections sealed
Corrosion resistance class CRC 1 – Low corrosion stress
Vibration resistance Transport application test with severity level 1 to FN 942017-4 and EN
60068-2-6
Shock resistance Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Max. cable length 50 m system communication
Note on max. cable length Power supply according to nominal voltage
Cleanroom suitability, measured according to ISO 14644-14 Element installed statically, no meaningful evaluation possible
according to ISO 14644-1
KC mark KC-EMV
Note on materials RoHS compliant
Material housing Makrolon®
Nickel-plated die-cast zinc
Material o-ring Fluoro rubber
Diagnostics via LED Diagnostics per module
Network error
Power supply, electronics/sensors
Load power supply
System diagnostics
Maintenance required
Diagnostics via bus Electronics/sensors overvoltage
Load overvoltage
Electronics/sensors undervoltage
Load undervoltage
Diagnostics per internal communication Module error
Output short circuit/overload
Short circuit/overload in sensor supply
Load supply undervoltage
Fieldbus interface Ethernet
Field bus, protocol PROFINET IRT
PROFINET RT
Fieldbus interface, function Bus connection incoming/outgoing
Field bus, connection type 2x socket
Field bus, connection system M12x1, D-coded to EN 61076-2-101
Field bus, connection pattern 4
Field bus interface, electrical isolation Yes
Field bus interface, transmission rate 100 Mbit/s
Max. address volume, inputs 1024 Byte
Max. address volume, outputs 1024 Byte
Configuration support GSDML file
Communication interface, connection type 2x socket
Communication interface, connection technology M8x1, D-coded according to EN 61076-2-114
Power supply, connection type Plug
power supply, connection system M8x1, A-coded to EN 61076-2-104
Power supply, connection pattern 00991171
Power transmission, connection type Socket
Power transmission, connection technology M8x1, A-coded to EN 61076-2-104
Note regarding operating voltage SELV/PELV fixed power supplies required
Note the voltage drop
Nominal operating voltage DC of load 24 V
Permissible voltage fluctuation of load ±25%
Nominal DC operating voltage, electronics/sensors 24 V
Permissible voltage fluctuations for electronics/sensors ±25%
Intrinsic current consumption at nominal operating voltage for electronics/sensors Typically 80 mA
Intrinsic current consumption at nominal operating voltage load Typically 5 mA
Reverse polarity protection Yes

Application Notes

Check the complete model code, installed connections and operating limits against the original equipment. Products in the same series may differ in size, stroke, actuation, pressure range or mounting details.

Selection and Installation

Compare the original nameplate and part number with the product-specific datasheet. Follow the equipment manufacturer instructions for installation and commissioning, and clarify uncertain options before ordering.

Inquiry

For a quotation or replacement enquiry, provide model CPX-AP-I-PN-M12, part number 8086607, quantity, destination and clear photos of the original unit when available.

Datasheet Selection Note

Festo lists degree of protection as IP65 IP67 for part number 8086607. Confirm the full model code and the matching connection, operating range and mounting arrangement against the installed product before ordering.

Spare Parts Records

Keeping a clear record of installed components can make future maintenance and purchasing more efficient. For this product, record the brand, full model code, important specifications, and equipment location. Update the record whenever a component or machine configuration changes, so the next replacement decision is based on current information.

Product Inquiry Support

We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.

Additional information

Brand

FESTO

Model

CPX-AP-I-PN-M12

Part Number

8086607

Dimensions (W x L x H)

45 mm x 170 mm x 35 mm

Type of mounting

On DIN rail via accessories With through-hole

Max. number of modules

80

Product weight

186 g

Ambient temperature

-20 °C … 60 °C

Storage temperature

-40 °C … 70 °C

Relative air humidity

5 – 95% Non-condensing

Degree of protection

IP65 IP67