FESTO CPX-FB38 552046 Bus Node

The Festo CPX-FB38 (part number 552046) is a bus node. Its product datasheet lists operating voltage range dc as 18 … 30 V and ambient temperature as -5 … 50 °C.

SKU: 552046 Category: Tags: , , Brand:

Description

FESTO CPX-FB38 552046 Bus Node

The Festo CPX-FB38 (part number 552046) is a bus node. Its product datasheet lists operating voltage range dc as 18 … 30 V and ambient temperature as -5 … 50 °C.

Key Features

  • Operating voltage range DC: 18 … 30 V
  • Ambient temperature: -5 … 50 °C
  • Dimensions W x L x H: (including interlinking block) 50 mm x 107 mm x 50 mm
  • Intrinsic current consumption at operating voltage: Typ. 100 mA

Technical Data

Brand FESTO
Model CPX-FB38
Part number 552046
Dimensions W x L x H (including interlinking block)
50 mm x 107 mm x 50 mm
Fieldbus interface 2x socket, M12x1, 4-pin, D-coded
Device-specific diagnostics Channel and module-orientated diagnostics
– Undervoltage of modules
– Diagnostic memory
Configuration support XML file
Parameters configuring – Diagnostic behaviour
– Failsafe response
– Forcing of channels
– Signal setup
– System parameter
Additional functions System status can be represented using process data
Additional diagnostics interface for operator units
Control elements DIL switches
Baud rate 100 MBit/s
Operating voltage range DC 18 … 30 V
Intrinsic current consumption at operating voltage Typ. 100 mA
Nominal operating voltage DC 24 V
Corrosion resistance classification CRC 1 – Low corrosion stress
Storage temperature -20 … 70 °C
Protection class IP65
IP67
Ambient temperature -5 … 50 °C
Product weight 125 g
Maximum address volume for outputs 64 Byte
Maximum address volume for inputs 64 Byte
Protocol EtherCAT
Bus-specific LED display Error: communication error
L/A1: network active, port 1
L/A2: network active, port 2
Run: Communication status
Product-specific LED display M: Modify, parameterisation
PL: load supply
PS: Electronics supply, sensor supply
SF: system error
Material housing PA-reinforced

Application Notes

Check the complete model code, installed connections and operating limits against the original equipment. Products in the same series may differ in size, stroke, actuation, pressure range or mounting details.

Selection and Installation

Compare the original nameplate and part number with the product-specific datasheet. Follow the equipment manufacturer instructions for installation and commissioning, and clarify uncertain options before ordering.

Inquiry

For a quotation or replacement enquiry, provide model CPX-FB38, part number 552046, quantity, destination and clear photos of the original unit when available.

Datasheet Selection Note

Festo lists dimensions w x l x h as (including interlinking block) 50 mm x 107 mm x 50 mm for part number 552046. Confirm the full model code and the matching connection, operating range and mounting arrangement against the installed product before ordering.

Functional Check After Replacement

After fitting the replacement, follow the equipment commissioning procedure before returning the machine to normal operation. Where applicable, test under controlled conditions and observe response, movement, signals, leakage, and connection stability. Check the installation again after its initial run to identify any adjustment that may be needed.

Product Inquiry Support

We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.

Additional information

Brand

FESTO

Model

CPX-FB38

Part Number

552046

Dimensions W x L x H

(including interlinking block) 50 mm x 107 mm x 50 mm

Fieldbus interface

2x socket, M12x1, 4-pin, D-coded

Device-specific diagnostics

Channel and module-orientated diagnostics – Undervoltage of modules – Diagnostic memory

Configuration support

XML file

Parameters configuring

– Diagnostic behaviour – Failsafe response – Forcing of channels – Signal setup – System parameter

Additional functions

System status can be represented using process data Additional diagnostics interface for operator units

Control elements

DIL switches

Baud rate

100 MBit/s