IMI Norgren 0820750 8D Series G1/4 Electro-Mechanical Pneumatic Pressure Switch
IMI Norgren 0820750 is an 8D diaphragm pressure switch with a G1/4 port and a 0.5-30 bar switching range.
Description
IMI Norgren 0820750 is an 8D diaphragm pressure switch with a G1/4 port and a 0.5–30 bar switching range.
Product Identification
| Model | 0820750 |
|---|---|
| Model | 0820750 |
| Pressure connection | G1/4 |
| Switching pressure range | 0.5–30 bar |
Inquiry
Send the full part number, required quantity and a photo of the existing part or its label so the required version can be checked.
0820750 Pressure and Connection Data
| Parameter | Value |
|---|---|
| Switching range | 0.5–30 bar (7.2–435 psi) |
| Pressure port | G1/4 |
| Electrical entry | Pg 13.5 cable gland |
| Pressure-sensor body | Aluminium |
| Seal | NBR |
| Fixed switching difference, lower / upper range | 1.2 / 2.2 bar |
8D Operating Conditions
| Parameter | Value |
|---|---|
| Medium | Neutral gaseous fluids |
| Operating principle | Diaphragm |
| Maximum overpressure | 50 bar; not a switching-range limit |
| Repeatability | ±2% of final value, depending on regulating pressure |
| Maximum viscosity | 1000 mm²/s |
| Ambient temperature | −10 to +80 °C |
| Media temperature | 0 to +80 °C |
| Switching rate | 60 cycles/min |
| Protection | IP64 for the specified cable-gland or Form A configurations |
| Mass | 0.4 kg |
8D Contact Ratings
| Voltage | AC resistive | AC inductive (cos φ 0.7) | DC resistive | DC inductive (L/R ≈10 ms) |
|---|---|---|---|---|
| 24 V | 5 A | 4 A | 2 A | 1 A |
| 60 V | 5 A | 2.5 A | 0.9 A | 0.3 A |
| 110 V | 5 A | 1.5 A | 0.45 A | 0.09 A |
| 230 V | 5 A | 0.9 A | 0.2 A | 0.02 A |
0820750 Mounting Drawing 1
| Parameter | Value |
|---|---|
| Height shown | 135 mm |
| Front width | 33 mm |
| Side extent shown | 72.5 mm |
| Pressure connection | G1/4 |
| Cable gland | Pg 13.5 |
Setpoint Selection
The manufacturer recommends setting the switch near the middle of its pressure range. The pressure reference is atmospheric.
Fixed Hysteresis
Switching difference is fixed rather than separately adjustable. The model row provides separate typical differences for the lower and upper parts of the range.
Cable-Gland Version
This configuration uses a cable gland; the Form A connector exclusion does not describe the cable-gland version.
Cold Air Supply
Below +2 °C, the air must be dry enough to avoid ice formation.
Load Derating and Connection
The electrical ratings are referenced to +30 °C and 60 cycles per minute. At +70 °C permissible current is half the tabulated value. Use suitable suppression for inductive loads, and do not assume the Form A terminal diagram describes the cable-gland wiring.
Installation Preparation
Prepare the equipment according to the site procedure and the manufacturer's instructions before installing this part. Where relevant, isolate power and pressure sources, then check the mounting direction, connection points, and sealing arrangement. After installation, inspect the completed connections before beginning a controlled functional test.
Product Inquiry Support
We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.
Additional information
| Model | 0820750 |
|---|---|
| Order code | 0820750 |
| Pressure connection | G1/4 |
| Switching pressure range | 0.5-30 bar |