IMI Norgren 18-015-844 1/8 PTF 0-10 bar Stainless Steel Air Pressure Gauge
IMI Norgren 18-015-844 is a stainless steel air pressure gauge with 1/8 PTF connection, 0-10 bar range and glass crystal for compressed air service.
Description
The 18-015-844 is a stainless steel version of the Norgren 5PG gauge, described with a 1/8 PTF connection and a 0-10 bar range. In the series, stainless bodies use a glass crystal and a stainless steel connector instead of the plastic crystal and brass connector of the standard versions.
Key Features
- Stainless steel body for the gauge
- Glass crystal used with stainless bodies in the series
- Stainless steel connector in the series construction
- 1/8 PTF connection as described for this item
- 0-10 bar range with psi, bar and MPa graduations
Technical Data
| Model | 18-015-844 |
|---|---|
| Connection | 1/8 PTF |
| Range | 0-10 bar |
| Body | Stainless steel |
| Crystal | Glass (series stainless version) |
| Connector | Stainless steel (series stainless version) |
| Accuracy | 2% FS mid-range, 3% FS other ranges |
Selection Notes
The series does not print a separate stainless-steel model table, so the material statements are series-level: standard gauges may have steel or plastic bodies, while the optional stainless version uses glass and a stainless connector. Confirm the body marking on the delivered 18-015-844.
18-015 5PG series – materials and construction
| Component | Standard series | Optional stainless series |
|---|---|---|
| Body | Steel or plastic | Stainless steel |
| Crystal | Plastic | Glass |
| Connector | Brass | Stainless steel |
Stainless construction in the series
The 5PG series information separates the standard and stainless materials: standard steel or plastic bodies use a plastic crystal and brass connector, while the stainless option uses a glass crystal and stainless connector. This distinction matters in washdown or corrosive surroundings, but the exact 18-015-844 build should be verified from its marking.
Medium and pressure limits
The gauge family is intended for compressed air and inert gases, with a maximum pressure of 100% of full scale and a stated operating range of -34 to 80 C. Dry air is required at low temperature to avoid ice formation. These are series limits, not confirmation of a higher rating for the stainless variant.
Operating Conditions Check
Before selecting 18-015-844, confirm that the actual operating conditions fall within the specifications for the exact version being ordered. Relevant factors may include supply voltage, pressure, temperature, medium, and operating frequency, depending on the product type. Do not apply a series-wide maximum rating to an individual variant without checking its documentation.
Order Detail Confirmation
To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.
Additional information
| Model | 18-015-844 |
|---|---|
| Connection | 1/8 PTF |
| Range | 0-10 bar |
| Body | Stainless steel |
| Crystal | Glass (series stainless version) |
| Connector | Stainless steel (series stainless version) |