IMI Norgren R07-200-NNKG 1/4 ISO G parallel 0.3 to 7 bar Non-relieving Miniature Pressure Regulator
R07-200-NNKG is a miniature non-relieving pressure regulator with 1/4 ISO G parallel ports and an outlet adjustment range of 0.3 to 7 bar.
Description
The R07-200-NNKG combines a zinc body with a push-to-lock pressure-adjusting knob. Its non-relieving diaphragm does not vent downstream pressure through the regulator when the setting is reduced. This configuration is supplied without a pressure gauge.
Selection Notes for R07-200-NNKG
Use 1/4 ISO G parallel mating connections and keep the controlled outlet within 0.3 to 7 bar. The maximum inlet pressure is 20 bar; the outlet setting range is a separate limit.
Exact pneumatic configuration
| Parameter | Specification |
|---|---|
| Inlet and outlet connection | 1/4 ISO G parallel |
| Outlet adjustment range | 0.3 to 7 bar |
| Diaphragm | Non-relieving |
| Pressure gauge | Not included |
| Pressure adjustment | Snap-action knob; push in to lock |
| Medium | Compressed air and neutral gases |
Operating limits and construction
| Parameter | Specification |
|---|---|
| Maximum inlet pressure | 20 bar (300 psig) |
| Operating temperature | -35 to +65 C |
| Cold operation | Air must be sufficiently dry to prevent ice below +2 C |
| Body | Zinc |
| Bonnet, knob and valve seat | Acetal |
| Elastomers | Nitrile |
| Valve | Brass and nitrile |
Panel installation and service
| Parameter | Specification |
|---|---|
| Panel mounting hole diameter | 30 mm |
| Maximum panel thickness | 6 mm |
| Body width reference | 41 mm |
| Knob diameter reference | 28 mm |
| Service kit | 3407-01 |
| Service kit contents | Slip ring, diaphragm, valve seat with O-ring, valve and valve spring |
Pressure adjustment and downstream behavior
The 0.3 to 7 bar spring range is intended for the controlled outlet pressure, with inlet pressure limited to 20 bar. Push the snap-action knob inward after adjustment to lock the setting. The non-relieving diaphragm retains downstream air rather than exhausting it through the regulator. Reducing the knob setting alone does not provide a downstream vent path; the connected circuit must consume or release the excess pressure.
Compact installation and maintenance
Panel mounting uses a 30 mm hole and accepts a maximum panel thickness of 6 mm. The compact body has a 41 mm width reference and a 28 mm knob diameter. The applicable 3407-01 service kit contains the diaphragm, slip ring, valve seat with O-ring, valve and valve spring, matching the non-relieving construction.
Order Detail Confirmation
To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.
Additional information
| Model | R07-200-NNKG |
|---|---|
| Port size | 1/4 |
| Thread | ISO G parallel |
| Outlet pressure range | 0.3 to 7 bar |
| Regulation | Non-relieving |
| Gauge | Not included |
| Maximum inlet pressure | 20 bar |
| Medium | Compressed air and neutral gases |