IMI Norgren T55C1800 G1/8 In-line Non-return Valve
T55C1800 is an aluminium-bodied G1/8 in-line check valve for filtered compressed air, with a Cv of 0.59.
Description
Model T55C1800. The spring-loaded valve permits air flow in one direction and prevents reverse flow. Its silicone-free construction uses a POM valve element, a stainless-steel spring and nitrile sealing for lubricated or non-lubricated pneumatic systems.
Selection Notes for T55C1800
Select G1/8 parallel-thread connections and install in the required permitted-flow direction. Keep operation within 0.1 to 10 bar and -20 to +80 C; applications below +2 C require technical assessment.
Pneumatic performance
| Parameter | Specification |
|---|---|
| Connection | G1/8 BSPP |
| Function | One-way non-return |
| Medium | Filtered compressed air, lubricated or non-lubricated |
| Operating pressure | 0.1 to 10 bar |
| Flow factor Cv | 0.59; US gallon/minute convention |
| Operating temperature | -20 to +80 C |
| Weight | 0.53 oz |
Standard construction
| Parameter | Specification |
|---|---|
| Body | Aluminium |
| O-ring | Nitrile rubber |
| Valve element | POM |
| Spring | Stainless steel |
| Silicone | Silicone-free construction |
Installation dimensions
| Parameter | Specification |
|---|---|
| Overall length B | 1.67 in |
| Across flats A | 0.55 in |
| Thread C | G1/8 |
| Dimension D | 0.28 in |
| Dimension E | 0.28 in |
| Dimension F | 0.54 in |
| Dimension G | 0.16 in |
| Dimension H | 0.59 in |
One-way pneumatic isolation
The valve opens for flow in its permitted direction and closes against reverse flow. The spring-loaded design is intended for in-line installation in a compressed-air circuit. A Cv of 0.59 describes the flow coefficient under the US gallon/minute convention; it is not a fixed air delivery rate at every supply pressure.
Seal and body combination
This standard aluminium-body configuration uses a nitrile O-ring, POM valve and stainless-steel spring. It is suitable for filtered compressed air with or without lubrication. The silicone-free design avoids silicone in the valve construction; high-temperature FPM seal options are separate configurations and are not included here.
Thread and operating envelope
Both connections are G1/8 parallel threads. The 1.67 in overall length and 0.55 in across-flats reference support compact in-line installation and wrench access. The pressure range is 0.1 to 10 bar and the temperature range is -20 to +80 C. Operation below +2 C requires application-specific technical assessment.
Product Inquiry Support
We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.
Additional information
| Model | T55C1800 |
|---|---|
| Port size | G1/8 |
| Function | One-way non-return |
| Operating pressure | 0.1 to 10 bar |
| Flow factor Cv | 0.59 |
| Body material | Aluminium |
| Seal material | Nitrile |