IMI Norgren T60C4890 G1/2 Excess-Flow Air Fuse

T60C4890: G1/2 excess-flow shut-off valve with 68.2 SCFM shut-off flow at 100 psi, automatic reset and an aluminum body.

Request a Quote

SKU: T60C4890 Category: Tags: , Brand:

Description

The T60C4890 is an in-line air fuse for a flexible pneumatic hose. It is selected by shut-off performance as well as connection size.

Request a Quote

Selection Notes for T60C4890

Confirm hose length, bore, available supply pressure and required trip behavior together; port size alone does not establish suitability.

Flow and Trip Characteristics

Parameter Value
Connection G1/2, ISO G
Shut-off flow rate 68.2 SCFM at 100 psi supply
Pressure drop at shut-off flow 2.0 psi
Flow at 100 psi supply and 1 psi differential 49.2 SCFM
Weight 5.3 oz

Service Conditions

Parameter Value
Medium Filtered compressed air or inert gases; lubricated or non-lubricated
Maximum pressure 16 bar (232 psi)
Minimum pressure Depends on hose length and internal diameter
Operating temperature -20 to 80 degrees C
Cold operation Avoid freezing conditions; confirm use below 2 degrees C

Materials

Parameter Value
Body Aluminum
Internal parts Brass
Spring Stainless steel

Installation and Reset

Parameter Value
Position in circuit Between fixed supply pipework and the flexible hose
Protected section Hose downstream of the air fuse
Orientation Install in the correct flow direction
Reset behavior Automatic after the failure is corrected

Excess-Flow Operation

The T60C4890 closes when the flow reaches its shut-off condition, helping limit air loss from a failed downstream hose. At 100 psi supply its shut-off flow is 68.2 SCFM with a 2.0 psi differential. The normal-flow value of 49.2 SCFM is specified at a different, 1 psi differential and is not the trip setting.

Positioning in the Air Line

Install the valve directly between fixed supply pipework and the flexible hose, with the marked flow direction observed. Only the hose downstream of the valve is protected. If an upstream shut-off valve is fitted, open it slowly to control the initial surge and avoid an unintended trip.

Hose and Supply Selection

Match the nominal valve size to the hose and evaluate hose length, internal diameter and available supply pressure together. The supply must deliver enough flow to activate the air fuse under a hose-failure condition. A long or restrictive hose can change the pressure required for reliable operation.

Automatic Reset and Commissioning

A small residual flow allows the valve to reset automatically after the fault is corrected. Confirm normal equipment operation and the shut-off response during controlled commissioning. The aluminum body, brass internals and stainless steel spring are intended for filtered pneumatic service.

Product Inquiry Support

We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.

Additional information

Model

T60C4890

Connection

G1/2

Maximum pressure

16 bar

Shut-off flow

68.2 SCFM at 100 psi

Shut-off differential

2.0 psi