IMI Norgren 0820750 8D Series G1/4 Electro-Mechanical Pneumatic Pressure Switch

IMI Norgren 0820750 is an 8D diaphragm pressure switch with a G1/4 port and a 0.5-30 bar switching range.

Request a Quote

SKU: 0820750 Category: Tags: , , Brand:

Description

IMI Norgren 0820750 is an 8D diaphragm pressure switch with a G1/4 port and a 0.5–30 bar switching range.

Request a Quote

Product Identification

Model 0820750
Model 0820750
Pressure connection G1/4
Switching pressure range 0.5–30 bar

Inquiry

Send the full part number, required quantity and a photo of the existing part or its label so the required version can be checked.

0820750 Pressure and Connection Data

Parameter Value
Switching range 0.5–30 bar (7.2–435 psi)
Pressure port G1/4
Electrical entry Pg 13.5 cable gland
Pressure-sensor body Aluminium
Seal NBR
Fixed switching difference, lower / upper range 1.2 / 2.2 bar

8D Operating Conditions

Parameter Value
Medium Neutral gaseous fluids
Operating principle Diaphragm
Maximum overpressure 50 bar; not a switching-range limit
Repeatability ±2% of final value, depending on regulating pressure
Maximum viscosity 1000 mm²/s
Ambient temperature −10 to +80 °C
Media temperature 0 to +80 °C
Switching rate 60 cycles/min
Protection IP64 for the specified cable-gland or Form A configurations
Mass 0.4 kg

8D Contact Ratings

Voltage AC resistive AC inductive (cos φ 0.7) DC resistive DC inductive (L/R ≈10 ms)
24 V 5 A 4 A 2 A 1 A
60 V 5 A 2.5 A 0.9 A 0.3 A
110 V 5 A 1.5 A 0.45 A 0.09 A
230 V 5 A 0.9 A 0.2 A 0.02 A

0820750 Mounting Drawing 1

Parameter Value
Height shown 135 mm
Front width 33 mm
Side extent shown 72.5 mm
Pressure connection G1/4
Cable gland Pg 13.5

Setpoint Selection

The manufacturer recommends setting the switch near the middle of its pressure range. The pressure reference is atmospheric.

Fixed Hysteresis

Switching difference is fixed rather than separately adjustable. The model row provides separate typical differences for the lower and upper parts of the range.

Cable-Gland Version

This configuration uses a cable gland; the Form A connector exclusion does not describe the cable-gland version.

Cold Air Supply

Below +2 °C, the air must be dry enough to avoid ice formation.

Load Derating and Connection

The electrical ratings are referenced to +30 °C and 60 cycles per minute. At +70 °C permissible current is half the tabulated value. Use suitable suppression for inductive loads, and do not assume the Form A terminal diagram describes the cable-gland wiring.

Installation Preparation

Prepare the equipment according to the site procedure and the manufacturer's instructions before installing this part. Where relevant, isolate power and pressure sources, then check the mounting direction, connection points, and sealing arrangement. After installation, inspect the completed connections before beginning a controlled functional test.

Product Inquiry Support

We assist customers with industrial automation spare-part enquiries, including model confirmation, replacement questions, and initial photo comparisons. If you are unsure which version is installed, you may send the complete model code and clear photos of the nameplate or component. We will use the information provided to help review the enquiry and identify details that still need confirmation.

Additional information

Model

0820750

Order code

0820750

Pressure connection

G1/4

Switching pressure range

0.5-30 bar