IMI Norgren R07-200-NNKG 1/4 ISO G parallel 0.3 to 7 bar Non-relieving Miniature Pressure Regulator

R07-200-NNKG is a miniature non-relieving pressure regulator with 1/4 ISO G parallel ports and an outlet adjustment range of 0.3 to 7 bar.

Request a Quote

SKU: R07-200-NNKG Category: Tags: , Brand:

Description

The R07-200-NNKG combines a zinc body with a push-to-lock pressure-adjusting knob. Its non-relieving diaphragm does not vent downstream pressure through the regulator when the setting is reduced. This configuration is supplied without a pressure gauge.

Request a Quote

Selection Notes for R07-200-NNKG

Use 1/4 ISO G parallel mating connections and keep the controlled outlet within 0.3 to 7 bar. The maximum inlet pressure is 20 bar; the outlet setting range is a separate limit.

Exact pneumatic configuration

Parameter Specification
Inlet and outlet connection 1/4 ISO G parallel
Outlet adjustment range 0.3 to 7 bar
Diaphragm Non-relieving
Pressure gauge Not included
Pressure adjustment Snap-action knob; push in to lock
Medium Compressed air and neutral gases

Operating limits and construction

Parameter Specification
Maximum inlet pressure 20 bar (300 psig)
Operating temperature -35 to +65 C
Cold operation Air must be sufficiently dry to prevent ice below +2 C
Body Zinc
Bonnet, knob and valve seat Acetal
Elastomers Nitrile
Valve Brass and nitrile

Panel installation and service

Parameter Specification
Panel mounting hole diameter 30 mm
Maximum panel thickness 6 mm
Body width reference 41 mm
Knob diameter reference 28 mm
Service kit 3407-01
Service kit contents Slip ring, diaphragm, valve seat with O-ring, valve and valve spring

Pressure adjustment and downstream behavior

The 0.3 to 7 bar spring range is intended for the controlled outlet pressure, with inlet pressure limited to 20 bar. Push the snap-action knob inward after adjustment to lock the setting. The non-relieving diaphragm retains downstream air rather than exhausting it through the regulator. Reducing the knob setting alone does not provide a downstream vent path; the connected circuit must consume or release the excess pressure.

Compact installation and maintenance

Panel mounting uses a 30 mm hole and accepts a maximum panel thickness of 6 mm. The compact body has a 41 mm width reference and a 28 mm knob diameter. The applicable 3407-01 service kit contains the diaphragm, slip ring, valve seat with O-ring, valve and valve spring, matching the non-relieving construction.

Order Detail Confirmation

To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.

Additional information

Model

R07-200-NNKG

Port size

1/4

Thread

ISO G parallel

Outlet pressure range

0.3 to 7 bar

Regulation

Non-relieving

Gauge

Not included

Maximum inlet pressure

20 bar

Medium

Compressed air and neutral gases