IMI Norgren 11-818-110 11-818 Series Precision Pressure Regulator

IMI Norgren 11-818-110 is the high-pressure 11-818 Series precision compressed-air regulator, with G1/4 ports and a 0.4-10 bar outlet adjustment range.

Request a Quote

Description

IMI Norgren 11-818-110 is the high-pressure 11-818 Series precision compressed-air regulator, with G1/4 ports and a 0.4-10 bar outlet adjustment range.

Request a Quote

Product Identification

Model 11-818-110
Series 11-818
Ports G1/4
Adjustment range 0.4-10 bar

Inquiry

Send the full part number, required quantity and a photo of the existing part or its label so the required version can be checked.

11-818-110 Model Configuration

Parameter Value
Regulation range 0.4-10 bar (5.8-145 psi)
Maximum inlet pressure 14 bar (203 psi)
Accuracy, typical 0.05 bar at mid-range; 7 bar inlet and 2 dm³/s
Relieving Standard
Gauge port None on this model
Tamper-proof screw Not listed for this model
Mass 0.64 kg

Air Supply, Temperatures and Materials

Parameter Value
Medium Oil-free compressed air; 5 µm prefiltration required
Ambient and medium temperature 0 to +70 °C (no-gauge version)
Body and bonnet Zinc alloy
Adjusting knob Acetal resin
Elastomers NBR

High-Pressure Variant Curve Reference

Parameter Value
Flow curve test inlet 14 bar
Regulating curve nominal outlet levels Approximately 6.3, 8 and 10 bar; curves are operating examples, not a flow rating
Pressure range of plotted variant 0.4-10 bar

Mounting Dimensions

Parameter Value
Body footprint 54 × 54 mm
Height shown 127 mm
Knob diameter shown 43 mm
Panel hole Greater than 12 mm diameter
Panel thickness Less than 6 mm

Separate Mounting and Service References

Parameter Value
Bracket D50159014
High-pressure service kit 2787-97
Gauge accessories For gauge-port versions; 11-818-110 has no gauge port. Accessories are not represented as included.

Pilot-Operated Regulation

The compact regulator incorporates an integral pilot for close pressure control and has provision for panel mounting.

Relief and Dead-End Use

This is not a constant-bleed device. Air bleed is effective under zero-flow conditions, and this series is not recommended for dead-end applications.

Compressed-Air Quality

Use oil-free compressed air and 5 µm prefiltration. Below +2 °C, the air supply must be dry enough to prevent ice formation.

Flow Curve Selection

Use the high-pressure curves when comparing outlet pressure across demand and inlet variations. The standard and low-pressure curves describe different variants.

Gauge Port and Service Parts

Do not assume a gauge port or gauge is included. The drawing limits the gauge port to the listed gauge-port variants; the high-pressure service kit is a separate part.

Functional Check After Replacement

After fitting the replacement, follow the equipment commissioning procedure before returning the machine to normal operation. Where applicable, test under controlled conditions and observe response, movement, signals, leakage, and connection stability. Check the installation again after its initial run to identify any adjustment that may be needed.

Order Detail Confirmation

To help prepare an accurate spare-parts order, please include the full model code, required quantity, and delivery destination in your enquiry. Photos or existing purchase records may be useful when a suffix or replacement choice is uncertain. Product details, payment method, and shipping arrangement can then be reviewed together before order processing.

Additional information

Model

11-818-110

Series

11-818

Ports

G1/4

Adjustment range

0.4-10 bar