IMI Norgren 1811705 G1/2 Pressure Switch
Norgren 1811705 is a G1/2 pressure switch for neutral or aggressive media, with +/-1% repeatability in the series.
Description
The 1811705 is a pressure switch with a G1/2 port from the Norgren 5.11.221 series. The series is intended for neutral, aggressive and non-inflammable gases and fluids, with a diaphragm or piston sensing element and a microswitch contact.
Key Features
- G1/2 port
- Series range -1 to 100 bar
- Repeatability +/-1% of final value
- Fixed or adjustable hysteresis options
- Microswitch SPDT contact in the series
Technical Data
| Model | 1811705 |
|---|---|
| Port | G1/2 |
| Series range | -1 to 100 bar |
| Repeatability | +/-1% of final value |
| Switching cycles | 20/min maximum |
| Media | Neutral, aggressive, non-inflammable gases and fluids |
Selection Notes
The exact 1811705 model row is not printed in the extracted pages, so the switching range and hysteresis of this unit must be confirmed from its label or order record before setting a control point. The series range is wide and must not be used as the set range of this switch.
5.11.221 series – technical data
| Parameter | Value |
|---|---|
| Operating pressure | -1 to 100 bar |
| Repeatability | +/-1% of final value |
| Port size | G1/2 |
| Media viscosity | Up to 1000 mm2/s |
| Switching cycles | 20/min maximum |
| Hysteresis | Fixed or adjustable |
Setting a pressure switch
The series repeatability is quoted as plus or minus 1 percent of the final value, which matters when the switch is used for an alarm or interlock near the ends of its range. The set point and hysteresis should be adjusted with a reference gauge and then checked over several cycles.
Media and sealing
The switch is intended for neutral, aggressive and non-inflammable gases and fluids, with a stated sealing rate of 10-7 mbar l/s or better. Check that the wetted materials suit the actual medium, and do not use the switch for inflammable media outside the manufacturer's approval.
Installation Preparation
Prepare the equipment according to the site procedure and the manufacturer's instructions before installing this part. Where relevant, isolate power and pressure sources, then check the mounting direction, connection points, and sealing arrangement. After installation, inspect the completed connections before beginning a controlled functional test.
International Delivery Options
We can discuss international delivery arrangements according to the order and destination. FedEx, UPS, DHL, or another suitable express service may be considered based on the shipment requirements. Please provide the delivery location and product details during the enquiry so that the available shipping arrangement can be confirmed before the order is processed.
Additional information
| Model | 1811705 |
|---|---|
| Port | G1/2 |
| Series range | -1 to 100 bar |
| Repeatability | +/-1% of final value |
| Switching cycles | 20/min maximum |
| Media | Neutral, aggressive, non-inflammable gases and fluids |