IMI Norgren 20AG-X4G-PD100 G1/2 0.07-3.5 bar High Flow Pressure Regulator
Norgren 20AG-X4G-PD100 is a G1/2 high-flow pressure regulator with a 0.07-3.5 bar outlet range and relieving diaphragm.
Description
The 20AG-X4G-PD100 is a high-flow pressure regulator described with a G1/2 port and a 0.07-3.5 bar outlet range. The 20AG family uses a large diaphragm and a balanced valve, which The series presents as giving quick response to flow changes and limiting the effect of inlet-pressure variation on the outlet setting.
Key Features
- Large diaphragm for quick response to flow changes
- Balanced valve to reduce inlet-pressure effect on outlet
- T-bar adjustment with relieving diaphragm
- Maximum inlet pressure 28 bar (406 psi) in the series
- 1/8 in ISO Rc gauge port
Technical Data
| Model | 20AG-X4G-PD100 |
|---|---|
| Port | G1/2 |
| Outlet range | 0.07-3.5 bar |
| Max inlet | 28 bar (406 psi) |
| Gauge port | 1/8 in ISO Rc |
| Adjustment | T-bar, relieving diaphragm |
| Temperature | -34 to 80 C (dry air) |
Selection Notes
The supplied 20AG series information covers 3/4 in and 1 in ported versions; the G1/2 variant and its 0.07-3.5 bar spring are not listed in that ordering table. Use the series data as background and confirm the port, range and adjustment on the delivered regulator.
20AG series – technical data
| Parameter | Value |
|---|---|
| Medium | Compressed air only |
| Maximum inlet pressure | 28 bar (406 psi) |
| Port sizes (series) | 3/4 in PTF, 1 in PTF, G3/4, G1 |
| Gauge port | 1/8 in ISO Rc |
| Ambient/media temperature | -34 to 80 C |
| Body / bonnet | Zinc alloy / aluminium alloy |
Balanced valve behaviour
The 20AG series information explains that the balanced valve reduces the influence of inlet-pressure changes on the outlet setting, while the large diaphragm gives a quick response when flow demand changes. For a low outlet range such as 0.07-3.5 bar, this behaviour matters when the upstream supply varies during the shift.
Relieving diaphragm and gauge port
The listed 20AG models use a relieving diaphragm and T-bar adjustment, and provide a 1/8 in ISO Rc gauge port. The relieving feature allows downstream pressure to fall when the set point is reduced; the gauge port can be used for a pressure gauge or left plugged, depending on the installation.
Functional Check After Replacement
After fitting the replacement, follow the equipment commissioning procedure before returning the machine to normal operation. Where applicable, test under controlled conditions and observe response, movement, signals, leakage, and connection stability. Check the installation again after its initial run to identify any adjustment that may be needed.
International Delivery Options
We can discuss international delivery arrangements according to the order and destination. FedEx, UPS, DHL, or another suitable express service may be considered based on the shipment requirements. Please provide the delivery location and product details during the enquiry so that the available shipping arrangement can be confirmed before the order is processed.
Additional information
| Model | 20AG-X4G-PD100 |
|---|---|
| Port | G1/2 |
| Outlet range | 0.07-3.5 bar |
| Max inlet | 28 bar (406 psi) |
| Gauge port | 1/8 in ISO Rc |
| Adjustment | T-bar, relieving diaphragm |